8. Replacing the filter

Use only original Soehnle filters!
Proceed as follows to change the filter:
1. Switch the device off and disconnect the
power plug.
2. Remove the water tank (1.1).
3. Lift the upper housing from the bottom
housing (1.2).
4. Remove the filter (1.3).
5. Insert the new filter.
6. Place the upper housing back on the
lower housing. Insert the water tank into
the housing and ensure that the water
tank is inserted securely and correctly.

9. Transport and storage

Transport
WARNING!
Always switch the device off before trans­
porting it. Always disconnect the power plug
from the power outlet. Transport the device
only when it is empty.
Storage
We recommend carefully cleaning your Air­
fresh Hygro 500 before storing the device.
Ensure that all parts are clean and dry prior
to storing the device. Do not leave water in
the lower housing. Water that remains in the
Airfresh Hygro 500 may result in mineral de­
posits and promotes the growth of unde­
sired micro­organisms. Store the Airfresh
Hygro 500 in a cool and dry location.

10. Troubleshooting

Problem: The device does not work
• Ensure that the air container is connected
to a power source.
• Ensure that the water container is filled
with water and that the container is insert­
ed correctly.
Problem: Air humidity does not change
• Ensure that the filter is inserted correctly.
• Ensure that the filter is clean. Please clean
the filter if it is heavily soiled.
• Ensure that your room is not excessively
ventilated and close windows and doors.
• Ensure that the size of your room corre­
sponds to the recommended size of this
device.