LEGRAND KEOR LINE RT 1000 VA Manuel D'installation page 41

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
MODEL NUMBER
Battery Parameters
Type
Quantity x Voltage x Rating
Backup Time
50% Charge
Recharge Time
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Operating Altitude
Audible Noise
Standard and certifications
Safety
EMC
Markage
KEOR LINE RT 1000, 1500, 2200, 3000 VA
1000VA
(3 100 45)
Valve-regulated, nonspillable, lead acid
3x36x7
>10'
after full discharge into resistive load
Up to 10,000 ft. (3000m) at 95°F (35°C) without derating
1500VA
2200VA
(3 100 46)
(3 100 47)
3x36x9
6x72x7
>8'
5 hours to 90% of rated capacity,
+32°F to + 104°C (0°C to + 40°C)
+5°F to + 104°F (-15°C to + 40°C)
0% to 95%90%, non-condensing
<40 dBA, internal fan(s) Off
<45 dBA, internal fan(s) On
EN-62040-1
EN-62040-2
CE
3000VA
(3 100 48)
6x72x9
>8'
>8'
41

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Keor line rt 1500 vaKeor line rt 2200 vaKeor line rt 3000 va

Table des Matières