• Installation (picture number 1a ABS version)
Position the wall niches of the jet nozzles as shown in the drawings
Function
Position first stage wall and wall components flush with structural concrete. Remove protective covers only when ready to lay tiles/
mosaics. In the case of a concrete/liner pool first stage components may project in order to compensate for cement render or liner
insulation thickness. First stage components must be accessible from the outside of the pool wall to allow for the installation of
pipes and air suction lines later. Locate the pneumatic switch housing in a convenient position 15-20 cm below water level. After
having installed the first jet, the others (3 - 5) should be located either at a laterial distance approx. 1.5 m from the first, either in a
straight line horizontally at approx. 1.5 m from the last jet or diagonally to a distance of 60 cm from the bottom of the pool. It is
advisable to make provision for protecting the pneumatic tube (PVC 2/4 dia.) and air inlet tubes (PVC 12/21 dia.) by placing in
protective conduit or through adjacent cable/ventilation ducts.
• Tile plan (picture number 2a and 3a ABS version)
Render and tile to inner edge. Render & tile 6 cm max.
• Pools with plastic liner (picture number 4a ABS version)
• Steel, aluminum and polyester pools (picture number 6 red bronze version and 6a ABS version)
• Pneumatic switch (picture number 5 red bronze version and ABS version)
5
liner
clamping
frame
one rubber
gasket to
either side
screw
of liner
6
rubbergasket
screw 6 x 30
clamping frame
clamping frame
screw 6 x 30
dimensions in cm
pool wall
water level
15 - 20
gasket
proposal:
nozzle housing 3- 5 may be
installed horizontally at 1,5 m
centre approx. or diagonally to a
distance 60 cm from pool-floor
gasket
24
12
nozzle housing
60°
Ø 0,7
use clamping
8,6
frame for cutting
and drilling
~ 60
suction tube
Ø 0,7
stopper 2"
suction housing
45°