SAFETY INSTRUCTIONS

1.1 Before Setting into Operation
Before installation and setting into operation, the Safety Instructions and the Operating Instructions must be carefully read and
observed. You must definitely comply with the requirements of the uwe company and of the standards authorities.
1.2 Setting the Unit into Operation for the First Time
Before the unit is set into operation, the local safety regulations and the Safety Instructions must always be complied with.
1.3 Sources of Danger
Warning!
The JETSTREAM system forces up to 1200 litres of water per minute into the pool through the nozzle. If all of this enormous force
is used for massage, it can cause injuries to muscles and to connective tissue, as well as internal injuries. Because of the reduced
electrical resistance of the human body in swimming pools and the resulting increased probability of the occurrence of dangerous
currents in the body, increased safety requirements are imposed on the electrical installation.
Therefore, you must definitely observe the following Safety Instructions:
The JETSTREAM has substantial power. Before massage, you must definitely reduce the pressure.
Do not utilize full thrust against soft parts of the body.
Warning
Switch off pump before adjusting angle of nozzle.
For large-area massage, reduce the strength to half thrust.
In order to attach and detach the massage fitting switch off the pump.
To massage a single part of the body, grip the massage hose firmly. When using the hose keep a distance to
those parts of the body that require massaging.
Do not approch the suction filter with long hair unless tied back.
Before putting the massage hose on or taking it off, switch off the pump.
For point massage, hold the nozzle of the massage hose firmly in your hand under water. Guide the nozzle of
the massage hose over the required places but at some distance from them.
Do not dive to the intake screen (if there is one) with long, unrestrained hair.
For requirements regarding the appropriate electrical installation, please see „Information for the Electrician". Parts of the equip-
ment that contain electrically live parts must be inaccessible to persons using the pool. Units and unit parts containing electrical
components must be installed or fixed in such a way that they cannot fall into the water. Units of enclosure class I must be
permanently connected to permanently laid cables.
1.4 Proper Operation
All units are intended soleley for operation in covered swimming pools and in open-air swimming pools with a water temperature
up to 35°C. The units are suitable for installing and operating in installations and rooms in areas 1 and 2 as per EN-60335-2-41.
The pump is normally installed in the walkway behind the pool wall, but it must be ensured that the environment is dry and that the
motor is protected by a suitably sized floor drain to prevent flooding. The control panel should be installed either in a dry walkway
or in an adjacent room, if possible higher than the water level. Any kind of use other than the intended use is improper. The
manufacturer will not accept liability for any damage or injury resulting from improper operation; the user alone must bear this risk.
Proper operation also includes compliance with the operating, maintenance and repair conditions specified by the manufacturer.
Maintenance work, repair work and suchlike may only be performed by authorised persons. The units may only be used by
persons who are familiar with them and who have been informed about the dangers. The relevant regulations for the prevention of
accidents and the other generally recognised rules relating to safety and to occupational medicine must be complied with. If
unauthorised modifications are made on the units, the manufacturer will not accept liability for any resulting damage or injury.
1.5 Product Liability
The user's attention is expressly drawn to the fact that the unit may only be operated in the proper manner. If it is operated in an
improper manner, the user must bear sole responsibility. In such cases, therefore, the manufacturer cannot accept any liability.
1.6 Procedure in an Emergency
Leave the water immediately, switch off the electrical supply to the unit by operating the main power switch or circuit-breaker, and
secure the unit to prevent it from being switched on again without authorisation.
1.7 Explanation of the Danger Symbols
Warning!
In these Operating Instructions, we have used this symbol to mark all texts which relate to your safety. Please
pass all safety instructions on to other users too.
Warning
In these Operating Instructions, we have used this symbol to mark all texts containing instructions that are
necessary for functional reasons. Please be sure to obey these instructions in order to avoid damage to the
unit.