Factory settings are guide values only
at 120% This pre set value ens
at 120%. This pre-set value ensures that only a defined charge energy quantity is made. It
can also be used as a an charge overload protection. When the pre-set value is reached,
the charger switches itself off.
Operating Instructions
Power Peak ® Twin EQ-BID
Activate the line "CUT. TEMPER." by pressing the "DEC"-
ture can be entered, when reached, the charge process will
be interrupted. The set-up can be set in the range between
10 ° C - 65 ° C in steps of 1 ° C.
In the line "MAX.CAPACITY", the maximum charged capa-
city is given as a percentage depending upon the defined
battery capacity set.
Adjustment range: 10...150% for NiCd- and NiMH- bat-
teries, Lithium- and Pb-batteries 10...120%. Using BID
connection NC/NiMH fixed at 150% and Lithium/ lead fixed
Using the "SAFETY TIMER" mode will allow a time limit to
be set for the charge-discharge process. The adjustment
range is between 20 and 300 minutes. Additionally, the
Safety Timer can be switched OFF.
In the column "CHARGE RATE", the desired charge rate
can be set-up.
med between 1- 5 C.
Note:
Pay attention to the maximum charge rate of your battery!
Activate the line "PEAK DELAY" for both NiCd- and NiMH-
batteries by pressing the "DEC"- or "INC"- buttons , a Pre-
Peak delay function can be used also. This overrides the
peak detection at the start of the charge of batteries with a
high internal resistance. The delay can be set in 1 minute
steps from 1...20 minutes.