MAG welding torches

9.1 Cable assembly

9.2 Torch neck
10 Troubleshooting
 See Fig. 2 on page EN-9
1 Unscrew the cable assembly (8) on the machine side and bring it into a
stretched position.
2 Unscrew retaining sleeve (6) and pull out liner (7) and replace it, if
necessary.
3 Remove worn parts (1), (11), (9), (10) from the torch neck (2).
WARNING

Risk of injury

Serious injuries caused by parts swirling around.
• When cleaning the wire guide liner with compressed air, wear suitable
protective clothing, in particular safety goggles.
4 Clean wire conduit (3) from both sides with compressed air.
5 Slide adjusted liner (7) into wire conduit (3) and secure with retaining
sleeve (6).
 See Fig. 3 on page EN-10
6 Connect cable assembly on the machine side with wire feed unit (8).
1 Remove gas nozzle.
2 Remove welding spatter and spray gas nozzle using the ABICOR BINZEL
anti-spatter agent.
3 Check wearing parts for visible damage and replace them, if required.
NOTE
• Some problems are listed below, with descriptions of possible causes
and solutions. If the measures described below are not successful, please
consult your dealer or the manufacturer.
• Please also consult the operating instructions for the welding
components, such as the power supply, welding torch system, re-
circulating cooling unit, etc.
10 Troubleshooting