►►5. CONNECTION TO THE
MAINS ELECTRICITY
CHECK YOUR ELECTRIC SYSTEM IS
EARTHED CORRECTLY.
Before connecting the heater to the mains
electricity, make sure that the power
supply voltage and frequency are correct
(see data plate applied to the heater).
The connection to the mains electricity
(Pic. 10) must be made in compliance
with the National Standards in force.
►►6. IGNITION FOR MANUAL
MODELS (... / ...M / ...DV / ...M DV)
IMPORTANT: For ...DV / ...M DV models,
check the position of the transformer
switch (220-240V / 110-120V) (Pic. 11).
If the voltage set on the appliance does
not correspond to that supplied by the
mains, the voltage must be adapted.
Loosen the 2 lid screw fasteners (Pic.
12), shift the switch onto the voltage
value supplied (Pic. 13) and re-mount
the lid (Pic. 14).
VERIFY
THE
BETWEEN
POWER
SUPPLY,
SETTING
VOLTAGE SWITCH AND TYPE OF
PLUG, BECAUSE IMPROPER USE
MAY CAUSE DAMAGE TO THE
HEATER.
● 6.1. HEATING MODE:
►6.1.1.Take the "O/I" switch to position
"I" (Pic. 15).
►6.1.2.Press the gas button fully home
and hold it down (Pic. 16).
►6.1.3.Activate the piezoelectric igniter
fully home and repeatedly (Pic. 17),
keeping the gas button pressed (Pic. 16).
►6.1.4.After ignition of the flame, hold
the gas button down for about 15 s (Pic.
18).
CONGRUENCE
TENSION
OF
DUAL
►6.1.5.Release the gas button (Pic. 19).
In the event of a power cut or if there is
no gas supply, the appliance will switch
off. The heater does not switch back
on automatically. It must be switched
on manually by repeating the switch-on
procedure.
If the appliance does not switch on,
consult the relative section (Par. 13.
"TROUBLESHOOTING").
● 6.2. VENTILATION MODE:
The heater can also be used as a fan.
Connect the heater to the mains electricity
(Pic. 10) and take the "O/I" switch to
position "I" (Pic. 15).
N.B.: With the heater functioning
in heating mode, before passing to
ventilation mode, carry out the correct
switch off sequence for the manual
models [Par. 9. "SWITCH-OFF FOR
MANUAL MODELS (... / ...M / ...DV / ...M
DV)"].
►►7. IGNITION FOR
ELECTRONIC MODELS (...E /
...ET)
►7.1.Take the "O/I" switch to position "I"
(Pic. 15).
►7.2.Press the "RESET" button (Pic.
20).
The heater starts the analysis sequence
and the flame ignites after about 20÷30 s
(see functioning layout Pic. 21).
In the event of a power cut or if there is
no gas supply, the appliance will switch
off. The heater does not switch back on
automatically. It must be switched on
manually by pressing the "RESET" button
(Pic. 20).
If the appliance does not switch on,
consult the relative section (Par. 13.
"TROUBLESHOOTING").