3. Intended use

The infrared thermometer enables contract-free measurement of surface-temperatures. It determines temperature
according to the radiated infrared energy that is emitted by every object. Contact-free measurement makes it ideal
for dangerous, difficult to access, moving or live objects. It cannot measure through transparent media such as glass,
plastics, water, etc. Instead, the surface temperature is measured at all times. The temperature measuring range is
from -50 to +1600 °C. A double laser target device facilitates determination of the measuring range.
Additionally, a contact measurement with a thermal element sensor type K is possible in the measuring range from -50
to +1370 °C, depending on the sensor used. This contact sensor must only be used on voltage-free media.
The installed sensors can be used to measure ambient temperature and relative humidity. These measured values
can be used to calculate and display the dew point and the evaporation temperature (wet bulb). There is a mould
warning display.
An integrated camera permits recording images and videos with the measured data displayed there. The data can
be recorded in the integrated storage or on an optional microSD memory card. A data logger with curve memory is
present.
The IR-thermometer as such must not come directly into contact with the measured contact and surface temperature.
A sufficient safety distance and the admissible ambience conditions must be complied with under all circumstances.
Diagnostic application in the medical area is not admissible.
The degree of emissions can be adjusted to the present surface property of the measured object. A table of common
materials is integrated.
The installed USB interface serves only as a charging interface. Data transmission is not possible.
A 3.7 V Li-ion battery of type 18500 with a connection plug is used for voltage supply. No energy supply other than the
one indicated can be used. Charging is performed via the integrated USB charging interface.
The enclosed USB plug-in mains adapter is designed in protection class 2 and must only be used in dry inner rooms.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product for purposes
other than those described above, the product may be damaged. In addition, improper use can result in short circuits,
fires, electric shocks or other hazards. Read the instructions carefully and store them in a safe place. Make this prod-