LOCATION
The installation location must allow adequate clearance for servicing and proper operation. A minimum front
clearance of 40" (1016 mm) is required. Side and rear clearance varies based on range top and adjacent materials
of construction:
Side – French Plate, Griddle
Side – Hot Top
Combustible Material includes materials made of or surfaced with wood, compressed paper, plant fibers, or
other materials that are capable of being ignited and burned.
even though flame-proofed, fire-retardant treated, or plastered. [definition courtesy ANSI]
INSTALLATION CODES AND STANDARDS
Your Vulcan range must be installed in accordance with state and local codes, or in the absence of local codes,
with National Electrical Code ANSI/NFPA-70 (latest edition) available from The National Fire Protection
Association, Batterymarch Park, Quincy, MA 02269. In Canada refer to Canadian electrical code C22.1 Part 1
(latest edition).
ASSEMBLY
Leg/Caster Assembly
The range is shipped fully assembled, except for the legs.
stainless steel legs (hardware included), packaged in a box located inside of the oven.
casters or 6" adjustable casters are available as an optional field installable accessories.
RANGE SERIES
EV12
EV24
EV36
EV48
EV60
EV72
Clearance Requirements
Rear
LEGS TO INSTALL
Combustible
1"
6"
0"
Such material shall be considered combustible
The range is provided with 6"(152 mm) adjustable
4
4
4
8
8
8
6
Non-Combustible
0"
0"
0"
A set of 6"(152 mm)
CASTERS TO INSTALL
4
4
4
8
8
8