FEATURES
1. Laser emitting window
2
2. Keypad
3. ON/OFF knob (transport lock)
4. Battery compartment cover
5. ¼" thread for tripod
1
6. 5/8" thread for tripod
7 . Hole for hanging position
8. Fixing screw for the universal mount
9. Slot for belt fixing
10. Magnets
7
3
4
5
5
6
9
8
10
D
OPERATION
Setting up the laser:
1. on the floor
2. connect the laser to the mount supplied with the kit and connect it to a tripod
3. fix the magnets of the mount onto a magnetic surface (steel plate)
4. set up the laser in a hanging position by means of the hole of the mount
5. connect the laser to a column by means of the fixing strap
POWER ON
Power on the laser by turning the ON/OFF knob in position ON. The
instrument is now ready for use. An audible and optical (blinking lines)
alarm indicates if the instrument was set up outside of the compensator
range. Set up the instrument on a more even surface.
To power the instrument off turn the ON/OFF knob back to the OFF position. The instrument is now
powered off.
NOTE:
During transport the ON/OFF knob (compensator lock) must be set to OFF . Disregard may lead to
damages of the compensator.