Installation
• For the glass door version: When ambient humidity is above 65 % in 25 °C
(77 °F) ambient temperature, moisture will condense on the door.
• The socket outlet for the mains connection must be freely accessible.
• When the cooling device is positioned, the supply cord must not be trapped or
damaged.
Ventilation (fig. 3, page 4)
• Ventilation must be provided as shown in alternatives A, B, C or D.
• Ventilation grills (1), if used, must have openings of at least 200 cm² (31 sqin)
each.
• The minimum clearance between the cooling device's back and the surrounding
structure should be as follows:
No. in
fig. 3, page 4
2
3
• The ventilation duct must at least measure 105 mm (4.13") x the width of the cool-
ing device.
• Only the entire cooling unit must project into the ventilation duct as shown.
• Air passing through the ventilation duct must not be preheated by any source of
heat.
• The ventilation duct must be kept free from any obstacles. Especially portable
multi socket outlets or portable power supplies, which can get warm, must not
be kept at the rear of the cooling device.
5.1
Fixing the cooling device
➤ Fix the cooling device through its fixing feet as shown (fig. 2, page 3).
5.2
Changing the decorative plate
➤ Change the decorative plate as shown (fig. 4 to fig. 7, page 5).
5.3
Mounting the sliding hinge (optional)
You can mount a sliding hinge that allows the cooling device door to be opened at
the same time as the door of the built-in cabinet.