Permissible operating temperature of the application (referred to the
maximum power which can be supplied):
N95000 and NF503A
Ta: -25...+55°C (T6)
Ta: -25...+60°C (T5)
Ta: -25...+70°C (T4)
Maximum effective internal inductance (Li) and capacitance (Ci):
Li = 100 µH, Ci = 90 nF
The values apply to potted connection wires which are 0.5 m long.
.
3 Installation remarks / Installation
Adhere to the relevant national regulations and provisions.
Avoid electrostatic charging on plastic units and cables.
Protect unit and cable against destruction.
The units must not be installed in the partition between different zones.
In principle, the type test only takes atmospheric conditions into account.
For conditions outside these ranges use must be assessed and approved
by the user.
The equalisation of potential of metal housing parts must be ensured by
appropriate mounting.
4 Connection configurations
5 Maintenance / Repair
The unit must not be modified nor can it be repaired. In case of a fault
please contact the manufacturer. If needed, you can obtain data sheet or
type test certificate from the manufacturer.
73024995a
© Elster GmbH | All rights reserved. Subject to modification
Honeywell
7