BM2 BIEMMEDUE SUPER 150 Manuel D'emploi Et D'entretien page 27

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GB
ATTENTION
In case of a prolonged inactivity of the high pressure cleaner it is possible that, to the first ignition, the high pressure cleaner is not
able to reach the correct pressure of exercise: in that case use the following instructions.
• Stop the machine as instructed before "TURNING OFF".
• Disconnect the electrical supply turning off the disconnecting switch on the electrical switchboard.
• Close the water mains cock and unscrew the hose coupling (1) of the water entrance pipe.
• Remove the high pressure cleaner body unscrewing the side leaflets.
• Unscrew the hose coupling (2) of the float chamber/pump link (yellow) pipe Venturi (3).
• Screw the hose coupling of the water entrance pipe (1) to the link Venturi (3).
• Open the water mains cock and put the electrical supply.
• Switch the high pressure cleaner on pressing the magneto-thermal switch black key "I".
• Pull the automatic handle lever and point the water jet at the surface to be cleaned; after 1-2 minutes of working verify that the
high pressure cleaner has joint the correct pressure on the manometer.
• Repeat the turn off operations to stop the high pressure cleaner and turning off the electrical and hydraulic supply.
• Unscrew the hose coupling of the water entrance pipe (1) to the link Venturi (3).
• Screw the hose coupling (2) of the float chamber/pump link (yellow) pipe Venturi (3).
• Replace the high-pressure cleaner body screwing the side leaflets.
• Unscrew the hose coupling (1) of the water entrance pipe.
2
3