Technical data

Drive
Operating pressure (fl ow pressure) 87 psi (6 bar)
Sanding shoe
15-3/4" x 3-5/32" (400 x 80 mm)
Speed
Working strokes
Sanding stroke
Air consumption at nominal load
Weight

Functional description

Accessories shown or described are sometimes
not included in the scope of delivery.
[1-1] On/Off switch
[1-2] Speed control
[1-3] Button for loosening the IAS connection
[1-4] IAS connection adapter
[1-5] Sanding shoe
1
1-1
Compressed-air supply and com-
missioning
Make sure that the pneumatic tool
is switched off when you connect the compressed-
air supply.

Compressed-air preparation

The Festool service unit VE should always be used
to ensure that Festool pneumatic tools function
correctly. Consisting of a fi lter, control unit, con-
densation drain and lubricator, the service unit
cleans and lubricates the compressed air and
keeps it free of condensation. Here, the lubrica-
tor should be set so that a drop is applied to the
compressed air approx. every 7-10 minutes.
Compressed-air vane motor
5,500 - 7,000 rpm
11,000 - 14,000 rpm
5/32" (4 mm)
390 l/min
5.0 lbs (2.3 kg)
1-2
1-3
LRS 400
incorrect compressed-air processing is excluded
from warranty claims.
We recommend a service unit with a 3/8" connec-
tor, when up to two Festool pneumatic tools are
used. A compressor that supplies at 500 l/min and
at an operating pressure of 6 bar (87 psi) should
be used to supply compressed-air. The diameter
of the piping system must be suffi ciently large (at
least 9 mm (3/8")).
The eccentric sander is a pneumatic tool for con-
nection to the Festool IAS 3 system.
This hose system combines three functions in
one hose:
- Compressed air supply [2-1]
- Exhaust air extraction [2-1]
- Dust extraction [2-1]
2
1-4
2-1
1-5
2-2
2-3
Connection and disconnection – see Fig. [3].
IAS 3 connecting system – see accompanying
instruction sheet.
8
Damage that occurs as a result of

IAS hose connector

Publicité