maintenance

Before proceeding, follow the Pressure relief
Procedure outlined previously in this manual.
additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. always unplug the sprayer before
servicing!

General repair and Service Notes

The following tools are needed when repairing this sprayer:
Phillips Screwdriver
Needle Nose Pliers
Adjustable Wrench
Rubber Mallet
Flat-blade Screwdriver
1. Before repairing any part of the sprayer, read the instructions
carefully, including all warnings.
ImPOrTaNT: Never pull on a wire to disconnect it. Pulling on a
wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to be
sure that the problem is corrected. If the sprayer does not
operate properly, review the repair procedure to determine if
everything was done correctly. Refer to the Troubleshooting
Charts to help identify other possible problems.
3. Make certain that the service area is well ventilated in case
solvents are used during cleaning. Always wear protective
eyewear while servicing. Additional protective equipment
may be required depending on the type of cleaning solvent.
Always contact the supplier of solvents for recommendations.
4. If you have any further questions concerning your Titan Airless
Sprayer, call Titan:
Customer Service (U.S.) ..................................... 1-800-526-5362
Fax ................................................................. 1-800-528-4826
© Titan Tool Inc. All rights reserved.
3/8" Hex Wrench
5/16" Hex Wrench
1/4" Hex Wrench
3/16" Hex Wrench
5/32" Hex Wrench
5/64" Hex Wrench

replacing the Filters

Pump Filter
1. Loosen and remove the filter
body by hand.
2. Slip the filter off of the core
spring.
3. Inspect the filter. Based on
inspection, clean or replace the
filter.
4. Inspect the o-ring. Based on
inspection, clean or replace the
o-ring.
5. Slide the new or cleaned filter
over the core spring with the
filter spring adapter in place.
Push the filter into the center of
the filter housing.
6. Slide the filter body over the
filter and thread it into the filter
housing until secure.
NOTE: The filter housing
should be hand-
tightened, but make
sure the filter housing
is seated fully into the
pump block.
Gun Filter
1. Unclip the top of the trigger guard from the gun body.
2. Using the bottom of the trigger guard as a wrench, loosen and
remove the handle assembly from the gun head.
3. Pull the old filter out of the gun body. Clean or replace.
4. Slide the new filter, tapered end first, into the gun head.
5. Thread the handle assembly into the gun head. Tighten with
the trigger wrench.
6. Snap the trigger guard back onto the gun body.
NOTE: For more detail, part number information, and
complete assembly drawings, please see the rX-Pro
airless Gun Owner's manual.
9
Filter Body
Filter Spring
Filter
Filter Spring
Adapter
Core Spring
O-ring
Filter Housing
Gun
Body
Filter
Handle