Hazet-Werk SYSTEM 7000 eTAC Notice D'utilisation page 30

Clé dynamométrique à serrage couple et angle
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8 .8 Enabling menu access:
26. Press
to access the menu.
27. "Code, 0000" is displayed. The first digit is highlighted.
28. Enter the code by changing the highlighted code digits
with
. Confirm the entry with
highlighted. Change the other highlighted digits the same
way, by pressing
29. After the last confirmation with
option in the menu is displayed. Access to the menu is
re-enabled. Pressing
menu options to configure other settings. Pressing
shows the start display.
8 .9 PC connection
The "PC connection" menu option is required to connect the
torque wrench with built-in angle gauge to a PC via the USB
interface. The PC connection must be configured for reading
stored data and for programming the wrench with the optionally
available HAZET PC software.
30. To establish a connection to a PC, change to the menu
with
and select the "PC connection" menu option
with
.
31. Pressing
in the "PC connection" menu option displays
".....".
32. The torque wrench with built-in angle gauge is ready to be
connected to the HAZET PC software. The subsequent
procedures for reading stored data and for programming
the wrench with the HAZET PC software are part of the
operating instructions for the HAZET PC software.
8 .10 . Application / operation of the
torque wrench with built-in angle
gauge
The torque wrench with built-in angle gauge must only be oper-
ated with the handle at right angles to the screw joint. The hand
force deployed must be applied uniformly onto the centre of the
handle (ring marking).
In order to avoid measurement errors when measuring the rotation
angle, do not allow the screwed workpiece or its support to turn,
move or sway during operation.
9 . Adjustment / calibration:
Electronic torque wrenches with built-in angle gauge should be
checked and calibrated on a regular basis. After a long period
of use, re-certification or re-calibration by the factory is advis-
able. Electronic torque wrenches with built-in angle gauges are
measurement tools. Appropriate measurement equipment must
be used to test (and where applicable, adjust) measurement tools
at the time intervals laid down by Quality Management.
The time gap between test dates is dependent on the frequency
of use. We recommend testing after approx. 5000 screw opera-
tions (but this should be no later than 6 months).
NOTICE! The "Version" menu option provides informa-
tion on the software version, the serial number, the date
of the last calibration and the remaining number of
releases until the next calibration of the wrench.
30
Design and function
. The next digit is
and confirming with
.
, the "Mode" menu
enables you to select other
(TOP version only):
1. To access the information in the "Version" menu option,
you must switch to the menu with
"Version" menu option with
2. The software version information is displayed after press-
ing
in the "Version" menu option.
3. Further information is shown on the second page of the
display. Use
to move to the 2nd screen and
return to the 1st.
and select the
.
to

Publicité

Table des Matières
loading

Table des Matières