Connecting The Drain; Door Reversal-Side Swing Only - Whirlpool GI15PDXZS Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Side View
1
⁷⁄₈
(1.9 cm)
20" (50.80 cm)
A. Drain hose
D. Center of drain should be 20" (50.8cm)
B. 1" (2.54 cm) air gap
from front of door, with or without the ¾"
C. PVC drain reducer
(1.91 cm) panel on the door. The drain
should also be centered from left to right
(8
13
Drain Pump System (on some models)
IMPORTANT:
Connect the ice maker drain to your drain in accordance with
the International Plumbing Code and any local codes and
ordinances.
The drain pump discharge line must terminate at an open
sited drain.
Maximum rise 10 ft (3.1 m)
Maximum run 100 ft (30.5 m)
NOTES:
If the drain hose becomes twisted and water cannot drain,
your ice maker will not work.
It may be desirable to insulate the drain line thoroughly
up to the drain inlet. An Insulation Sleeve kit, Part Number
W10365792, is available for purchase.
Do not connect the outlet end of the drain tube to a closed
pipe system to keep drain water from backing up into the ice
maker.

Connecting the Drain

After ensuring that the drain system is adequate, follow these
steps to properly place the ice maker:
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A
B
"
1" (2.5 cm)
C
2" - 1¹⁄₂"
(5 cm - 3.8 cm)
D
" from either side of the ice maker).
16
1. Plug into a grounded 3 prong outlet.
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
2. Style 1—For gravity drain system, push the ice maker into
position so that the ice maker drain tube is positioned over
the PVC drain reducer. See "Gravity Drain System."
Style 2—For drain pump system connect the drain pump
outlet hose to the drain. See "Drain Pump System."
3. Recheck the ice maker to be sure that it is level. See
"Leveling."
4. If it is required by your local sanitation code, seal the cabinet
to the floor with an approved caulking compound after all
water and electrical connections have been made.
Door Reversal—Side Swing Only
Tools Needed
Gather the required tools and parts before starting installation.
" wrench
5
16
¼" wrench
Hinge pin
Handle screw
Remove Stainless Steel Door Wrap Panel
(on some models)
A. Hex-head screws
1. Remove the 2 hex-head screws located under the stainless
steel door wrap panel flange on the bottom of the door.
2. Pull up and outward on the door wrap panel from the bottom.
3. Rotate the door wrap panel until it separates from the door
and pull up.
Flat putty knife
Phillips screwdriver
5
" hex-head hinge screw
16
End cap screw
A
9

Publicité

Table des Matières
loading