Troubleshooting / Repair Parts
SYMPTOM
Pump won't start or run.
Pump starts and stops.
Pump operates but
delivers little or no water.
For parts or assistance, call Flotec Customer Service at
PROBABLE CAUSE(S)
Pump is not plugged in.
Blown fuse or breaker.
Low line voltage.
Defective motor.
Motor is overheating.
Restricted discharge
(obstacle or ice in piping).
Restricted intake.
Low line voltage.
Worn or plugged impeller.
Anti-airlock hole is plugged.
1
1
2
2
3
3
4
4

CORRECTIVE ACTION

Check and see if pump is plugged in to a proper outlet.
If blown, replace with fuse of proper size or reset breaker.
If voltage under recommended minimum, check size of
wiring from main switch on property. If OK, contact power
company or hydro authority.
Replace pump.
Discharge or intake are obstructed. Pump is in too
shallow of water.
Remove pump and clean pump and piping.
Remove the pump and clean out the intake screen.
If voltage under recommended minimum, check size of
wiring from main switch on property. If OK, contact power
company or hydro authority.
Replace pump.
Turn off the pump, clean out the anti-airlock hole, and
restart the pump.

REPAIR PARTS

Key
Part Description
1
Power Cord
2
Adapter
3
Motor Assembly
4
Inlet Screen
** If the motor fails, replace the entire pump.