Resistance
Range
600.0 Ω*
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
60.00 MΩ
Overload protection 1000 V
Measuring voltage: approx. -0.5 V, measuring current approx. -0.7 mA
*Accuracy after deduction of the measuring line resistance
Capacity
Range
6.000 nF*
60.00 nF*
600.0 nF*
6.000 µF*
60.00 µF
600.0 µF
6.000 mF
60.00 mF
Overload protection 1000 V
*Accuracy for measurement range ≤ 1 µF only valid with the REL function used
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Resolution
0.001 nF
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
0.001 mF
0.01 mF
Accuracy
±(1.3% + 3)
±(1.0% + 3)
±(1.6% + 4)
±(2.6% + 7)
Accuracy
±(4% + 13)
±(4% + 7)
±10%