Connection with the mains.
The earth has to be connected. The device must only be connected with an electric installation carried out in
compliance with IEC standards.
Set up
Control panel
o
The control board offer several features :you can simple set the starting address, run the pre-programmed
program or make a reset
The main menu is accessed by pressing the Mode/Esc-button, Browse through the submenu by pressing Up
or Down .Press the Enter-button in order to select the desired menu. You can change the selection by
pressing Up or Down, Confirm every selection by pressing the Enter-button. You can leave every mode by
pressing the Mode/Esc-button .The functions provided are described in the following setting.
M ENU M AP
DMX Address (DMX address 001-512)
Mode (DMX mode 11/15 ch, Auto mode1~8,sound mode)
TEST mode (X,Y,Red,Green,Blue,White)
Language (Chinese,English,)
Setting (ID code0-25,X reverse,Y reverse,Fade delay,dmx singal,endcode,temperature
Protection,Temperature,fans seepd,screen protection,screen reverse, factory reset, rest motor,
System info (running time, total running time, software version, run mode, address, temperature
Note:output default setting address code is A001, pan is positive circumrotate、tilt is positive
circumrotate、LED positively reveal.
To set the pan to reverse
.Press the MENU until it shows RPOF.
.Use the UP/DOWN buttons show RPON, press ENTER to confirm.
To set the tilt to reverse
MOVING WASH 36x8Z Manual Ver. 1.02