The thermocooker is supplied with registers for primary and secondary air and a thermostat with which the combustion air is regulated.
1A - PRIMARY Air Register
With the lower register, the passage of primary air in the lower part of the cooker is regulated through the ash drawer and the grill in the
direction of the fuel. The primary air is necessary for the combustion process. The ash drawer must be emptied regularly, so that the
ash cannot block the primary air intake for combustion. The primary air also keeps the flame alive.
The primary air register must be almost completely closed during wood combustion, as otherwise the wood burns too quickly and the
thermo-product may overheat.
2A - SECONDARY Air Register
This register must be opened (and therefore shifted to the right), in detail, for the combustion of wood, so that unburnt carbon can be
subject to a post-combustion, increasing the yield and assuring the cleaning of the glass (see chapter NORMAL OPERATION).
The register regulation necessary in order to obtain nominal calorific output is the following (see Cap. TECHNICAL DATA):
Fuel
WOOD
B - AUTOMATIC Thermostat
The thermostat has the task of automatically increasing or decreasing combustion.
Dependent on the position chosen, the thermostat will act on the valve which regulates the intake of air into the furnace, placed on
the back of the cooker. Turn it in a clockwise direction from 0 to 5 to make up the fire and in an anti-clockwise direction to reduce
combustion. As this is an extremely precise device, it is advisable to turn it carefully and never force the knob.
C - FLUE GAS Register
(Picture 6 at page
(Conversion from the cooker HOTPLATE USE – OVEN USE function to the cooker HEATING function)
READY Model
On the right of the front of the stove/cooker, between the protection rail and the oven door, is the smoke-register control lever,
recognisable as a bronze knob. When the lever is pushed towards the back of the stove/cooker, the combustion gases flow above the
oven directly towards the exhaust stub (cooker function – PLATE USE); when the lever is pulled towards you, the combustion gases
flow all around the oven, so the internal temperature increases evenly (cooker – oven cooking and heating – OVEN USE).
XXL READY Model
When the control is positioned to the LEFT (on the pan symbol), the combustion gases flow above and around the oven (oven function
– HOTPLATE USE – OVEN USE); when positioned to the RIGHT (on the water symbol), the gases flow near the boiler, increasing the
temperature evenly, favouring water heating inside it (cooker function HEATING USE).
D - IGNITION Control - XXL READY Model
On the front of the cooker, between the protective handrail and the flue gas control, there is the ignition control lever, which can be
recognised by a chrome-plated knob.
This control must only be used to facilitate the ignition of fuel in the cooker. Pull the lever outwards from the cooker (control open).
IMPORTANT : during normal cooker operation, the control lever must remain completely inserted (pushed inwards on the cooker). In
this way avoiding excessive fuel consumption and poor thermocooker output (control closed).
To ignite the flame follow the instructions below (see Cap. IGNITION) :
give power supply
Switch on the digital controller (E). The appliance must only work with the controller ON
Open the ignition register to aid flue gas exhaust. Position the register (any butterfly valve placed on the flue gas exhaust pipe must
also be opened).
Position the thermostat knob on position 5 (maximum opening).
Open the primary air register (placed on the ash tray).
After having started the fire with small pieces of wood and waited until it is well lit, adjust the thermostat to the positions corresponding
to the desired heat (0÷5).
Bring the flue gas register to the oven position.
Close the any butterfly valve placed on the flue gas exhaust pipe must also be opened.
7097503
CHROME PLATED OVEN
GRILLE
OPTIONAL
OPTIONAL
SERIES
SERIES
(Picture 6 at page
97).
(Picture 6 at page
97).
PRIMARY air
1/2 OPEN
(Picture 6 at page
97)
97)
(Picture 6 at page
POKER
SERIES
SERIES
SERIES
SERIES
SECONDARY air
OPEN
97).
GLOVE
SERIES
SERIES
SERIES
SERIES
TERTIARY air
Pre-adjusted
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Temorosa xxl ready dsaTermorosa ready dsa 2.0Temorosa xxl ready dsa 2.0Termorosa ready - dsa

Table des Matières