enables the intake of cold water in the boiler coil, discharging the excess heat out of pipe C towards a conveniently installed drain. Cooling
circuit upstream pressure must be at least 1,5 bar - MAX 10 bar.
4.3.
SYSTEM CONNECTION AND FILLING
Some examples, purely indicative of the installation, are reported at chapter INSTALLATION LAY-OUT, while the connections to the
thermoproduct are reported at chapter DIMENSIONS .
ATTENTION: The filling of the TERMOROSA READY DSA system has to be filled only by means of the tap (pos. 3). When the
manometer (M) shows a pressure of 1-1,2 bar, close the tap.
During this phase, open all the bleed valves of the radiators to prevent the formation of air sacks, checking the outlet of water to avoid
unpleasant floodings.
The installation must always be full of water even when the thermo-product is not used. During winter season the non use has
to be faced by adding antifreeze substances.
5. FIRE SAFETY
When installing the product, the following safety measures must be observed:
a) In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing components flammable
and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with flammable structure (see
A). All the minimum safety distances are shown on the product data plate and lower values must not be used.
b) In front of the furnace door, in the radiation area there must be no flammable or heat-sensitive objects or material at a distance of less
than 100 cm. This distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is installed in front of the
whole component to protect.
c) If the product is installed on a non totally refractory floor, one must foresee a fireproof background. The floors made of inflammable
material, such as moquette, parquet or cork etc., must be covered by a layer of no-inflammable material, for instance ceramic, stone,
glass or steel etc. (size according to regional law). The base must extend at least 50 cm at the front and at least 30 cm at the sides, in
addition to the opening of the loading door (see
d) No flammable components (e.g. wall units) must be present above the product.
The Product must always operate exclusively with the ash drawer inserted. The solid combustion residues (ash) must be collected in a
sealed, fire resistant container. The Product must never be on in the presence of gaseous emissions or vapours (for example glue for
linoleum, petrol etc.). Never deposit flammable materials near the Product.
During combustion, thermal energy is released which leads to considerable heating of the surfaces, doors, handles, controls, glass parts,
the flue gas pipe and possibly the front part of the appliance. Avoid contact with these elements unless using suitable protective
clothing or accessories (heat resistant gloves, control devices).
Ensure children are aware of these dangers and keep them away from the furnace when it is on.
When using the wrong fuel or one which is too damp, due to deposits present in the flue, a flue fire is possible.
5.1.
IN A EMERGENCY
If there is a fire in the flue connection :
a) Close the loading door and the ash drawer door
b) Close the comburent air registers
c) Use carbon dioxide ( CO
d) Request the immediate intervention of the Fire Brigade
DO NOT PUT OUT THE FIRE WITH WATER.
When the flue stops burning, have it checked by a specialist to identify any cracks or permeable points.
6. TECHNICAL DESCRIPTION
La NORDICA thermocookers are ideal for holiday flats and weekend houses or as auxiliary heating all year round. Wooden logs are used
as fuel. The appliance works as an intermittent operating appliance.
The thermocooker is composed of galvanised steel sheet plates, enamelled cast iron and thermoradiant ceramic. The furnace is found
inside the boiler made with 4 mm thick steel and reinforced with welded nails. The water from the heating system, which absorbs the
heat produced in the furnace, circulates in the boiler. Inside the furnace, there is a height-adjustable flat grill
OPTIONAL a grill is also available for the OVEN (SERIES - XXL READY Model).
The furnace is equipped with a panoramic door with ceramic glass (resistant up to 700°C). This allows a fascinating view of the burning
flames. In addition, in this way there is no possibility of sparks or smoke escaping.
The heating of the room takes place:
a)
by means of radiation: through the panoramic glass and the hot external surfaces of the stove, heat is radiated into the room.
b)
by conduction: through radiators or convectors in the central heating system fed by the hot water produced by the Thermocooker
itself.
24
Picture 4 at page 96
powder ) extinguishers to put out the fire
2
TERMOROSA READY DSA 2.0 - TEMOROSA XXL READY DSA 2.0
- B).
Picture 4 at page 96
(Picture 8 at page
97). As an
7097503
-