Installation Example; Important - Franke AQRM698 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
2.

Installation example

a ..... Depth of recessed wall-mounting box
b ..... Distance from back face of recessed wall-mounting box to the centre of the pipe
c ..... Double-thickness panelling (12.5 mm/panel)
d ..... Distance from front face of adhesive flange to front face of recessed wall-
mounting box 6 mm
Ø .... Diameter of pipe connection spigot R1/2
e ..... AQUAFIX cross-beam recessed wall-mounting box
f ...... Stand wall
g ..... Adhesive flange recessed wall-mounting box
h ..... Front face of recessed wall-mounting box
i ...... Permanently elastic jointing compound
j ...... Double-thickness panelling
k ..... Seal
m .... Reinforcement strip
n ..... Tile adhesive
o ..... Tile
3.
Assembly
3.1
Fix the C profiles (a) to the profiles on the stand wall (b) using the screws.
The spacing of the C profiles depends on the chosen recessed wall-mounting box
Y= 124 or 200 mm.
3.2
Mount the threaded panels to the fixing cross-members using the screws. Do not
tighten the screws.

Important!

The hole spacing on the AQUAFIX cross-member is 120 mm.
3.3
Push through the two inner marks top and bottom with a screwdriver for fixing onto
the AQUAFIX cross-members.
3.4
Mount the recessed wall-mounting box on the cross-member using the screws.
3.5
Slide the fixing cross-members with recessed wall-mounting box in the pre-
assembled C profiles (a) on the stand wall (b).
3.6
Adjust the depth of recess of the recessed wall-mounting box in the stand wall (b).
Caution!
The distance between the front face of the adhesive flange (c) and the front face of
the stand wall (b) corresponds to the total material thickness of the panelling. That is
to say, the second panel layer lies flush with the front face of the adhesive flange.
3.7
Tighten the screws for fixing the cross-members.
3.8
Make the water connections.
3.9
Check the water connections for tightness.
3.10 Flush the pipes according to DIN 1988.
4

Publicité

Table des Matières
loading