Removing / replacing xenon tube
Unscrew the grub screw (2.0mm A/F hexagon key) in the flange of the cover 3 full turns (Do not fully unscrew). Unscrew
and remove the cover and lens assembly using the spanner supplied to gain access to the inside of the unit.
Remove the old tube by unscrewing the terminal block fixings. The replacement tube can now be fitted (see xenon tube
installation sheet, which is supplied with the replacement tubes)
Once the new tube has been correctly fitted, replace the cover assembly, ensuring the cover is fully screwed down. There
should be a maximum gap of 0.2mm between the faces of the cover and enclosure to ensure o-ring compression. Ensure
the cover seal is correctly seated in its groove during re-assembly. Re-tighten the grub screw (2.0mm A/F hexagon key)
in the cover flange to secure the cover.

6.0 SPECIAL CONDITIONS FOR SAFE USE

1. Painting and other surface finishes, other than those applied by the manufacturer, are not permitted
2. In order to maintain the dust tight integrity of the enclosures (IP6X), the threads of cable entry devices and
stopping plugs shall be sealed in accordance with the applicable code of practice for flameproof installation.
7.0 CERTIFICATION/APPROVALS
IECEx units
Certified to IEC60079-0, IEC60079-1 & IEC60079-31
Ex d unit (IEC certification No. IECEx BAS 05.0048X)
Ex d IIC T
Gb
G
Ex d IIIC T
Db IP66/67
D
T
amb.
Tube Energy
T-rating (T
15J & 10J
5J
The IECEx certificate and product label carry the IECEx equipment protection level marking
Gb
Db
Where Gb signifies suitability for use in a Zone 1 surface industries area in the presence of gas.
Where Db signifies suitability for use in a Zone 21 surface industries area in the presence of dust.
ATEX units
Certified to EN60079-0, EN60079-1 & EN60079-31
Ex d unit (ATEX certification No. Baseefa04ATEX0009X)
Ex d IIC T
Gb
G
Ex d IIIC T
Db IP66/67
D
T
amb.
Tube Energy
T-rating (T
15J & 10J
5J
09/14
)
T-rating (T
)
G
D
T4
T135°C
T5
T100°C
T6
T85°C
T5
T100°C
T6
T85°C
)
T-rating (T
)
G
D
T4
T135°C
T5
T100°C
T6
T85°C
T5
T100°C
T6
T85°C
T
amb.
(-55°C to +70°C)
(-55°C to +55°C)
(-55°C to +40°C)
(-55°C to +70°C)
(-55°C to +55°C)
(-55°C to +40°C)
T
amb.
(-55°C to +70°C)
(-55°C to +55°C)
(-55°C to +40°C)
(-55°C to +70°C)
(-55°C to +55°C)
(-55°C to +40°C)