MEDC Xénon XB15 Manuel Technique page 4

Masquer les pouces Voir aussi pour Xénon XB15:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Access to terminals
Unscrew the grub screw (2.0mm A/F hexagon key) in the flange of the cover 3 full turns (Do not fully unscrew). Unscrew
and remove the cover and lens assembly using the spanner supplied to gain access to the inside of the unit. Unscrew the
2 off thumbscrews and carefully lift the PCB assembly clear of the mounting pillars to gain access to the terminals.
Once termination is complete, replace the PCB assembly onto the mounting pillars and fully tighten the thumbscrews,
taking care not to overtighten them. Replace the cover assembly, ensuring the cover is fully screwed down. There should
be a maximum gap of 0.2mm between the faces of the cover and enclosure to ensure o-ring compression. Ensure the
cover seal is correctly seated in its groove during re-assembly. Re-tighten the grub screw (2.0mm A/F hexagon key) in
the cover flange to secure the cover.
09/14
WIRING DETAIL
© MEDC 2014

Publicité

Table des Matières
loading

Table des Matières