Westfire WF23 Notice D'installation Et D'utilisation page 13

Table des Matières

Publicité

Typical installation of an inset stove
Distance to Combustible materials
Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues
could ignite it. Therefore when installing the stove in the presence of combustible materials due account must
be taken of the guidance on the separation of combustible material given in Building Regulations Approved
Document J and also in these stove instructions.
Distance to combustible materials rear
Distance to combustible materials side
Distance to soft furnishing in front
Flue gas flow
The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove.
WESTFIRE · WF23
Vermiculite back fill insulation
Multi-fuel liner
Existing clay liner
Register plate
Supporting lintel
Adapter to appliance
(supplied by flue supplier)
Non combustible housing
Minimum height 500 mm for
glass floor plate 12 mm thick
Glass floor plate
WF23 / UNIQ23
200 mm
350 mm
1100 mm
5.2 g/sec
13
WF23 / UNIQ23 side glas
200 mm
450 mm
1100 mm
5.2 g/sec
UK

Publicité