Dometic CRX50 Instructions De Montage Et De Service page 36

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
Technical data
Total storage volume:
Voltage:
Power consumption (AC)
(ACDC models only):
Rated current
12 Vg:
24 Vg:
100 Vw (ACDC models only):
240 Vw (ACDC models only):
Cooling temperature range
Refrigerator:
Freezer:
Winter mode setting
(ACDC models only):
Climatic class:
Relative humidity:
Short-term inclination:
Max. pressure:
Propellant:
Refrigerant:
Refrigerant quantity:
CO
equivalent:
2
Global warming potential (GWP):
Dimensions:
Weight:
Inspection/certification:
Contains fluorinated greenhouse gases
Hermetically sealed equipment
36
CRX110
107.5 l
12 Vg or 24 Vg
100 – 240 Vw (ACDC models only)
50 W
6.2 A
3.0 A
0.82 A
0.34 A
+3 °C to +12 °C
–18 °C to –6 °C
T
Max. 90 %
maximum 30°
LP 11 bar/HP 25 bar
C
H
5
R134a
47 g
0.067 t
1430
fig. l, page 13
27.6 kg
CRX
CRX140
135 l
65 W
7.7 A
3.6 A
0.95 A
0.4 A
5 W heating,
off-cycle
10
50 g
0.072 t
fig. m, page 13
30.6 kg
E
4
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Crx65Crx80Crx110Crx140Crx série

Table des Matières