6.10 MAINTENANCE TO BE PERFORMED BY AN AUTHORISED TECHNICIAN
Task
General professional inspection
and servicing of the stove (& the
flue)
Clean/sweep the flue gas system
Replacement of parts that are not
mentioned in this manual
Check the connection between the
stove and chimney/the flue
All other service work not specifi-
cally mentioned in this manual.
Clean the room blower/flue blow-
er
Cleaning the stove inside and out
Lubricate the pellet auger gear
unit
Clean the smoke chamber
Check the ignition element
Clean the air side of the heat ex-
changer
Clean the flue side of the heat ex-
changer
Check the electrical parts such as
the PCB, the wiring, the sensors
and safety devices.
Check the silicon hoses on the pres-
sure sensor
Check the door seal and replace if
necessary.
Test the stove at all 5 combustion
levels
Test the safety devices
(*) The specified frequency is a minimum. Local law and/or your insurance contract
may prevail depending on which is stricter. If the stove is used intensively, the flue
must be cleaned more frequently.
7. TECHNICAL SERVICE, ORIGINAL SPARE PARTS
Before any stove leaves the factory, it is first thoroughly tested and started up. Any
repairs or commissioning work that proves necessary during or after installation
4
196
Frequency*
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Twice a season; the first time at the start of
the season
When damage is identified
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Once a season at the start of the season
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season at the end of the season
Once a season; at the end of the season or
after 900 combustion hours when the stove
displays SERV
Once a season
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Twice a season; the first time at the start of
the season or after 900 combustion hours
when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV