Page 5 of 5
7. CHLORINATION BOOST MENU
1. Press and hold the '+' button for 3 seconds to enter the menu dedicated to chlorination
2. The LEDs light up green.
3. Adjust the boost production using the buttons '+' and '-'.
From this moment on, production will be maintained for 24h as long as water is flowing
through the unit.
After this time period, the unit will return to its previous production situation.
If the LEDs light up yellow, the unit has not reached the desired production.
This may be due to various factors:
- Lack of salt.
- Scaled-up cell.
- Exhausted cell.
- Low water temperature.
Blue LEDs show the configured production and yellow LEDs show the actual production.
9. WATER FLOW ALARM
If the 3 LEDs in the centre are flashing orange, the unit is not producing.
This means that there is no water flow inside the installation. Check
- Flow switches,
- Configuration (see section 11),
- For correct flow.
10. REDUCING PRODUCTION USING THE COVER
1.
2.
3.
4.
5.
6.
When the cover contact is closed, the LEDs will automatically light up purple and
prodution will be limited to the programmed setpoint.
11. SELECTING THE FLOW SWITCH
1.
2.
3.
4.
USE ONLY GENUINE REPLACEMENT PARTS
boost.
8. 'LOW' ALERT
Connect the cover to the box (see section 5).
Press and hold the '-' button for 3 seconds to enter the menu dedicated to reduction
of production.
The LEDs light up purple.
Adjust to the desired production using the buttons '+' and '-'.
The reduction is applied to the production already configured.
Save the configuration by pressing the '+' button until you return to the previous
menu.
Connect the mechanical flow switch to the box (see section 5).
Press the '-' and '+' buttons simultaneously and hold for 3 seconds to enter the menu.
Select the position using the buttons '+' and '-'.
Position 1:
Gas sensor only.
Position 3:
Flow switch only.
Position 5:
Gas sensor + flow switch.
Save the configuration by pressing the '+' button until you return to the previous menu.
Salt & Swim 2.0
Rev. A