2. BATTERY TEST STATION:
FEATURES:
Reliable battery tester for all common cell types; Ultra fast testing; Indicates the battery voltage in V; Indicates the cell capacity in 10% steps.
THE FOLLOWING CELLS CAN BE TESTED:
ALKALINE CYLINDRICAL CELLS:
12 V: A23
1.5 V ALKALINE BUTTON CELLS:
1.44 V ZINC-AIR BUTTON CELLS:
3V LITHIUM BUTTON CELLS:
LITHIUM PHOTO CELLS:
3 V: CR 2; CR 123A; CR-V3
1.2 V NICD/NIMH RECHARGEABLE BATTERIES:
LCD-DISPLAY FOR BATTERY TEST STATION (2):
"CALC":
"80 %":
"1.53 V":
"Err":
On the display a battery bar graph symbol will be shown. This bar graph shows the capacity in %: 4 bars = 100-90%; 3 bars= 80 - 60 %; 2 bars= 50 - 30
%; 1 bar= 20 - 10%; no bar= 0%
OPERATION:
Once the device is connected to the mains (100-240 V AC) it is ready for use.
It is possible to charge rechargeable batteries in the charger, and to test batteries or rechargeable batteries at the same time.
How to make measurements:
On the underneath of the test pins is a compartment for the test pin (4). Open this compartment and remove the test pin carefully. Please do not damage
the cable to this test pin (it is fixed inside the compartment.) Close the compartment carefully with the test pin outside. There is an opening in the cover for
this purpose. The test pin can be stationed inside the opening (5), if not required.
1: Select the appropriate test terminal for the battery under test (see table (3)). 2: Place the battery on the test terminals, paying attention to the polarity.
(Both contacts must be connected). An additional test pin (4) should be used if testing cylindrical cells. This test pin must connect to the minus pole of the
cylindrical cell!. 3: Please connect the battery for approximately two seconds. The display shows "CALC". 4: The capacity of the cell will be shown in 10 %
steps for approximately two seconds. 5: The voltage of the cell will be shown in volts for approximately two seconds.
TIPS FOR BETTER TESTING:
Please ensure that the contacts of the test terminals and the contacts of the cells are clean; With a new battery it is possible that the full capacity may not
be shown. The cell needs to "wake up". Please test again.
IN CASE OF PROBLEMS:
"Err": Incomplete measurement. Please connect the cell for approximately two seconds.
With a deeply discharged cell the display may switch from "CALC" to "Err".
NO DISPLAY:
The device is not connected to the mains (100-240 V AC); The cell under test is deeply discharged; The cell under test is defective (High resistance etc.)
1.5 V: Micro AAA; Mignon AA; Baby C; Mono D; 9V
LR 43; LR 44; LR 45; LR 54; LR 55; LR 57; LR 59; LR 60; LR 66
V 675; V13; V 312
CR 1025; CR 1216; CR 1220; CR 1616; CR 1620; CR 2016; CR 2025; CR 2032; CR 2320; CR 2430; CR 2450
6V: CR-P2; 2CR5
Micro AAA; Mignon AA; Baby C; Mono D
Measurement (Calculation).
Cell capacity in 10%-steps.
Cell voltage in volts.
Error.