Installer's Set-up Parameters
To access the installation parameters menu, scroll to AUTO
(while in full mode), then press (OK) for 10s. Use (
keys to highlight the parameter to be adjusted. Press (OK) to
toggle the parameter setting, when the value starts to blink, use
Parameter
Name
dEG
Select temperature scale.
00:00
Select the hour format.
AIr
Calibration of the internal air sensor against the actual
room temperature.
(Air)
(The calibration must be done after 12 hours working at
the same set temperature).
CSP
Cooling set point.
HSP
Heating set point.
Selection of the number of valves to be driven.
Nb vAL
This parameter depends on the system design.
(2 Pipe
models only)
FAS SPEE
Allows the maximum fan speed to be switched off - the
unit will only run in Low and Medium speeds.
NIGt
Select option for fan speeds when the unit reverts to
night set back in cooling operation.
CLr ALL
Reverts the control back to factory settings.
End
Exit the installation menu.
Program Mode
Built-in Program Selection
A quantity of 9 built-in (P1-P9) and 4 user defined (U1-U4) timed
program options are available to choose from. Each day is
divided into 24 one hour periods operating in either Comfort
setting (21°C default heating and 22°C default cooling) or Night
) and (
)
Description
the (+) and (-) keys to adjust the value. Then, press (OK) to
confirm. Once parameters are set, go to <End> parameter and
press (OK) to go back to the main menu.
Default Setting
°C
12H
To adjust the air sensor temperature, enter the
measured temperature using the (-) or (+) keys.
To confirm the calibration, press (ok)
Press (+) and (-) keys at the same time to reset
the offset value.
The default water switching temperature for cooling
is 15°C, this can be altered by pressing (+) or (-) keys
then pressing (ok) to confirm.
The default water switching temperature for heating is
32°C, this can be altered by pressing (+) or (-) keys then
pressing (ok) to confirm.
0 valve
FA5
For Fast
NOr
(For Normal regulation)
Press (OK) for 5 seconds
set-back setting (19°C default heating and 24°C default cooling).
Scroll to the preferred program number P1-P9 (FIG 9, A) using
the (+) and (-) keys. The controls will then automatically go back
to AUTO mode.
Alternative Setting
°F
24H
1 valve
NEd
For Medium
AL1
(Fan speed 1 only)
Press (OK)
EN