iVECTOR
5.0 Controls
Note: When increasing the heating set-point beyond the cooling set
point, the cooling set point will increase in line with the heating
set-point. Additionally, if the heating set-point is increased further
until it reaches the cooling set-back temperature, the set-back
temperature will also increase with the heating set-point.
Display
1.
Heating indicator
2.
Cooling indicator
3.
Temperature symbol – when this is displayed
the current room temperature is displayed
4.
Fan speed symbol (fan blades will rotate when active)
5.
Comfort setting
6.
Power (on/off)
7.
Clock setting
8.
Room temperature
9.
Time
10.
Day of the week
11.
Auto setting (to follow set programme) - Full mode only
12.
Night set-back setting - Full mode only
13.
Holiday setting - Full mode only
14.
Program menu - Full mode only
15.
Program schedule - Full mode only
Keys:
OK
Validation key (OK)
+
Plus key (up)
-
Minus key (down)
Navigation left
Navigation right
Unit Operation
Turn on Electrical Supply
Easy Mode
(Factory Default)
Select Clock
Set Time
Select Comfort Setting
Set room temperature to
desired setting (default 21°C).
Fan runs in heating/cooling
Similarly, when decreasing the cooling set point below the heating
set-point, the heating set point will decrease in line with the cooling
set-point, and if the cooling set-point is decreased further until it
reaches the heating set-back temperature, the heating set-back
temperature will also decrease with the cooling set-point.
Press & hold (+) & (-)
for 5 secs to change
between modes
Use ( ) and ( ) keys to select
operating mode (Refer to
Full Mode
table on page 5)
Select Auto mode and
press (OK) for 10 secs
Setup Parameters
(Refer to table on page 6)
EN