DEFROSTING AND TANK CLEANING
To always achieve the highest performance we recommend
a manual defrosting when the frost layer on the tank walls
exceeds 5 mm thickness. Proceed as follows:
1)Put main switch off (if present) and unplug the unit.
2)Remove the product in another freezer at -18°C.
3)Remove the internal and external plugs from water
discharge tube placed on rear side of body; put below a tray.
3)Put a pot of warm water (not boiling) inside the tank after
having placed a sheet of carton-board on the botton, close
the lid and wait half an hour.
4)Wash the tank with water and neutral soap, rinse and dry
very well.
Make freezer work empty for an hour and then load food again.
Never use mechanical devices or any other means to ac-
celerate the defrosting process, other than those recommended by the manufacturer.
Do not use jet of water to clean the cabinet: electrical wiring could be damaged.
SEASONAL USE
When the unit is kept unused for a long time, please take note of the following procedures:
- unplug the unit;
- defrost, clean and dry well the unit;
- leave the lid open to avoid possible formation of bad odours.

MALFUNCTIONS AND REMEDIES

Most of the functioning inconveniences are generally due to simple causes or to defective electrical
connections. These problems can usually be solved on the place.
The unit does not start:
- check that there is voltage at the wall socket;
- check that the unit is properly plugged.
The internal temperature is not cold enough:
- check that the unit is placed near any heating source or placed on to a continuosly air flow action;
- check that there is not too much ice on the tank walls;
- check the temperature setting;
- check that the condenser is not blocked by dirt;
- check the perfect closing of the lid;
The unit is noisy:
- check that all the bolts and nuts are properly fasten;
- check that the unit is placed on an even surface;
- check if any pipe or fan is in contact with any other part of the body.