Dometic CRX50 Instructions De Montage Et De Service page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting
Number of
Fault
flashes
4
Speed too low
5
Overheating of the elec-
tronics unit
Constantly
Temperature sensor
errors
CRX110, CRX140
Number of
Fault
flashes
1
Low Voltage
2
Excessive fan current
3
The motor doesn't start The rotor is jammed.
4
Speed too low
5
Overheating of the elec-
tronics unit
Constantly
Temperature sensor
errors
30
Possible cause
If the cooling system is overloaded, the mini-
mum speed of the motor of 1,850 rpm can-
not be maintained.
If the cooling system is loaded too heavily or
the temperature is set too high, the electron-
ics can overheat.
Temperature sensor is defective.
Possible cause
The supply voltage is outside of the set range.
The fan load on the electronics unit is more
than 1 A.
The pressure difference in the cooling system
is too high (> 5 bar).
If the cooling system is overloaded, the mini-
mum speed of the motor of 1,850 rpm can-
not be maintained.
If the cooling system is loaded too heavily or
the temperature is set too high, the electron-
ics can overheat.
Temperature sensor is defective.