Beurer BC 32 Mode D'emploi page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
Blood pressure may vary between the right and left wrist,
which may mean that the measured blood pressure values are
different. Always perform the measurement on the same wrist.
If the values between the two wrists are significantly different,
please consult your doctor to determine which wrist should be
used for the measurement.
Correct posture
• Before the initial blood pressure measurement, make sure
always to rest for about 5 minutes. Otherwise there may be
divergences.
• You can perform the measurement
while sitting or lying. To carry out a
blood pressure measurement, make
sure you are sitting comfortably with
your arms and back leaning on some-
thing. Do not cross your legs. Place
your feet flat on the ground. Make sure
to rest your arm and move it. Always make sure that the cuff
is at heart level. Otherwise significant deviations can occur.
Relax your arm and the palm of your hand.
• In order not to distort the result, it is important to keep still
during the measurement and not talk.
Select memory
Switch on the blood pressure monitor with the
the required memory space by pressing the function key +. You
have two memories (60 memory spaces each) in order to save
the test results of 2 different people separately, or else save
measurements in the morning and evening separately.
Measuring blood pressure
• Put on the cuff as described previously and assume the posi-
tion in which you want to carry out the measurement.
• Using the buttons +, select the user memory 1 or 2. Start the
measurement process by pressing button
ing the display with all digits lighting up, the monitor will
automatically inflate. Following the self-test, during which all
display elements briefly appear, the measurement begins.
During inflation the device already determines measured val-
ues used to estimate the required inflation pressure. If this
pressure is insufficient, the device automatically inflates by
another.
• Then the pressure in the cuff is slowly released and the pulse
is measured.
• When the measurement has been completed, the remain ing
air pressure is released very quickly. The pulse, the systolic
and the diastolic blood pressure are displayed.
• You can interrupt measurement at any time by pressing the
button
• The
the measurement properly. Observe the section in these
instructions on error messages/troubleshooting and repeat
the measurement.
• The device switches off automatically after 1 minute.
button. Select
Wait for at least 1 minute before taking another meas-
urement.
20
.
icon appears if it has not been possible to perform
. After check-

Publicité

Table des Matières
loading

Table des Matières