Elixo 500 3S io
Stop (Fig. 8)
General closing (Fig. 10)
Movement not performed (Fig. 12)
Obstacle detection mode
When an obstacle is detected during opening, the gate will stop and partially reverse.
When an obstacle is detected during closing, the gate will stop and reopen.
Operation with a Situo, Telis or Composio type remote control (Fig. 13)
Operation with safety cells
An obstacle placed between the cells will prevent the gate from closing.
if an obstacle is detected when the gate is closing, it stops then reopens fully or partially depending on how it was programmed during installation.
If the cells are obscured for 3 minutes, the system switches to the "wired deadman operation" mode. In this mode, a command via a wired input causes
the gate to move slowly. The gate moves for as long as the command is issued and stops immediately when the command is discontinued. The system
switches back to normal operating mode as soon as the cells are no longer obscured.
Attention: the "wired deadman" mode requires the use of a safety contact (e.g. keyed reversing switch ref. 1841036).
The orange light is activated during any movement of the gate.
A 2-second pre-warning signal before movement starts may be programmed during installation.
5
8
STOP
10
General stop (Fig. 9)
Movement interrupted (Fig. 11)
12
13
STOP
9
STOP
11
STOP