Supply - Telwin PULSE 30 Instructions D'utilisation

Masquer les pouces Voir aussi pour PULSE 30:
Table des Matières

Publicité

- if necessary or requested by the vehicle
manufacturer
specifi cations,
voltage and/or current values as indicated below;
- use the "VOLT" button to select the battery voltage;
- connect the clamps to the relative vehicle battery
terminals;
- the process will run automatically indicating the
voltage value on the display (fi g. A.2), along with
the current (fi g. A.4) after 5 seconds from the last
operation.
DISPLAY - EXAMPLE

3.6.2 SUPPLY

Constant voltage generator that can be used on
BATTERY CHANGES or on batteries with a very
low voltage (below 2V) to try to increase their
voltage to a value that is suitable for starting with a
normal charge cycle.
FUNCTION SELECTION
ATTENTION! The set voltage is always
present on the charge clamps even when
disconnected from the battery.
ATTENTION! Pay particular attention to
the nominal voltage of the battery which must
correspond to the voltage selected using the
"VOLT" button and indicated on the display (fi g.
A.1). This function DOES NOT FORESEE spark
protection on the output clamps and polarity
reversal.
customise
DISPLAY
Customising VOLTAGE and CURRENT
the
VOLTAGE
- press and hold simultaneously the "VOLT" (fi g.
A.21) and "FUNCTION" buttons (fi g. A.22) for 3
seconds
- use the same buttons to select (decrease
using the "VOLT" button and increase using
the "FUNCTION" button) the desired voltage
value between 6V÷7.5V, 12V÷15V, 24V÷30V
respectively for 6V, 12V, 24V batteries; the factory
default voltage value is respectively 6.8V, 13.6V,
27.2V.
The set voltage mode will be exited automatically
after a 3" time-out.
VOLTAGE ADJUSTMENT - EXAMPLE
DISPLAY
CURRENT:
- press the "MODE" button until the desired value,
set as indicated in step 6, appears on the display
(fi g. A .4) and on the icon (fi g. A.6). The set current
mode will be exited automatically after a 3" time-
out.
CURRENT ADJUSTMENT - EXAMPLE
3A 7A 10A 20A 30A 40A
- 65 -
3"
BEEEP
13.3V
13.2V
13.1V
. . . . .
3A 7A 10A 20A 30A 40A
. . . . .
13.7V
13.6V
13.5V

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Doctor charge 30Doctor charge 50Lcd displayKey pad

Table des Matières