Operation And Maintenance - Simu T3.5 AUTO Notice Originale

Masquer les pouces Voir aussi pour T3.5 AUTO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
2
Wiring
230V ~ 50 Hz
N
L
PE
- 3 operators (max.) can be wired in parallel on one switch.
- Attach cables to prevent any contact with moving parts.
- If the motor is used outdoors and if the power supply cable is of the H05-VVF type, then run the cable in a UV-resistant conduit,
e.g. trunking.
- The motor can not be use with control devices such as: emergency power supply (ie: regulated power supply, power generating
unit, triac, ex, ....). Please contact us.
3
Power up of the operator
>>
After the first two consecutive and complete opening and closing of the shutter:
- The motor memorizes automatically the end limit ( up and down) positions.
- The «stop on obstacle» function is activated.
It is advised to carry out these two opening / closing cycles as soon as the product is installed.
For any further information, please consult the SIMU technical leaflet 5056893.
4
Cancelling the automatic settings
In the case of a new installation with this operator, it is advised to reset the motor according to the following procedure:
- Press 3 consecutive times, for 1s. each time, on the UP key. The motor runs briefly at each press.
- Press 3 consecutive times on the DOWN key. The first two press for 1s. (the motor runs briefly at each press) and the third press for
2s. The motor runs twice in the same direction.
>>
>>
1 s
1 s
5

Operation and maintenance

- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
Tips and recommendations for use:
Observations
The motorised product does not operate.
If the motorised product still does not work, contact a drive and home automation professional.
SIMU SAS, F-70103 GRAY as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and used as
intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in particular of the Machinery
Directive 2006/42/EC and EMC Directive 2014/30/EU. The full text of the EU declaration of conformity is available at www.simu.com.
Emmanuel CARMIER, general director, GRAY, 03/2017.
EN
2/2
T3.5 AUTO
>>
>>
1 s
Possibles causes
The overheating protection on the drive
has been activated.
N
L
PE
Blue
Black
Brown
Green/Yellow
>>
>>
>>
1 s
1 s
Wait until the motor cools down.
230V ~ 50 Hz
>>
>>
>>
>>
2 s
Solutions
T5 AUTO
1
2
3
>>

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T5 autoT3.5 auto+

Table des Matières