9
Cancelling programming & settings
9.1- Switch off the power supply to the motor for 2 seconds.
9.2- Switch the power to the motor back on for 7 seconds.
9.3- Switch off the power supply to the motor for 2 seconds.
9.4- Switch the power to the motor back on.
If the motor is on the end limit position (up or down), the
motor will run briefly in one direction and then in the other,
otherwise, the motor runs for 5 seconds in random direction.
The motor is now in the "cancelling mode".
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you
must "eject" out of this mode all the receivers that are not to be deprogrammed by sending a command
from their individual control transmitter (UP or Down).
9.5- Then, confirm the cancelling of the concerned motor from the individual control:
- Press the PROG key of the transmitter more than 7 seconds.
Maintain the pressure until the motor will first run for 0,5 second in
one direction and then in the other, and a few second later, it will run
again in both direction.
i
The motor is now as it was originally configured, and no transmitter
and no settings is saved in its memory and is ready for a new programming.
10

Operation and maintenance

- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
- If the motorised product is moving: briefly press the "Stop" button, the motorised product stops automatically.
- The motorised product is then stopped, press 0,5s on the "Stop" button. The motorised product moves to the
programmed intermediate position. (To modify or delete an intermediate position, see the section §7).
Tips and recommendations for use:
PROBLEMS
The motorised product does not
operate.
If the motorised product still does not work, contact a drive and home automation professional.
11

Technical Data

- Radio frequency 868-870 MHz, tri-band two-way.
- Frequency bands and Maximum power used:
868.000 MHz - 868.600 MHz ERP <25 mW
868.700 MHz - 869.200 MHz ERP <25 mW
869.700 MHz - 870.000 MHz ERP <25 mW
- Power supply: 230 V ~ 50 Hz
- Operating temperature : - 20 °C to + 60 °C
- Protection rating : IP44
- Safety level: Class I
Simu SAS, F-70103 GRAY as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage
230V~50Hz and used as intended according to these instructions, is in compliance with the essential requirements of the applicable
European Directives and in particular of the Machinery Directive 2006/42/EC, and the Radio Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at www.simu.com. Emmanuel CARMIER, general director, GRAY, 01/2018.
EN
4/4
POSSIBLE CAUSES
The overheating protection on the
drive has been activated.
The BHz control point battery is low.
9.1
9.2
9.3
OFF
ON
2
s
7s
9.5
PROG >7s
SOLUTIONS
Wait for the drive to cool down.
Check the battery and replace it
as required.
9.4
OFF
ON
2s
5s
>>
>>
2s
7s