11) VOX ~ VOX SET ~ M5
VOX
(short press)
The VOX function allows transmitting by speaking into the original microphone
(or in the optional vox microphone) without pressing the PTT switch (17). In
case of the use of an optional vox mike connected to the rear panel of the
radio - VOX MIC jack (D), the original microphone doesn't work.
Press shortly the VOX key in order to activate the VOX function. "VOX" is
displayed on the LCD. A new pressure on the VOX key switches the function
off. "VOX"disappears from the LCD.
VOX SET
(long press)
Press during 1 second the VOX SET key in order to activate the VOX SET func-
tion (if the VOX function is off, this will turn the function on and display "VOX"
on the LCD). The last selected adjust item appears.
Three adjustments are possible: Anti-Vox level (A), Sensitivity level (L), and Vox
delay time (t). Press shortly the VOX SET key in order to go to the following
adjustment. The display shows the type of adjustment by its first digit and its
level by the second digit.
- Sensitivity "L ": allows the adjustment of the microphone (original one or op-
tional vox) for an optimum transmission quality. Adjustable level from 1 (high
sensibility) to 9 (low sensibility) by rotating the channel knob or with the UP/
DN keys of the original microphone. L corresponds to the Sensitivity Level.
- Anti-Vox "A": allows disabling the transmission generated by the surrounding
noise. The level is adjustable 0 (Off) from 1 (high level) to 9 (low level) by
rotating the channel knob or with the UP/DN keys of the original microphone.
A corresponds to Anti-Vox.
- Delay Time "t": allows avoiding the sudden cut of the transmission by add-
ing a delay at the end of speaking. The level is adjustable from 1 (short time
delay) to 9 (long time delay) by rotating the channel selector or with the UP/
DN keys of the original microphone. t corresponds to delay time.
Once the adjustments are done, press during 1 second the VOX SET key in
order to quit the VOX SET function. If any adjustment have been done during
10 seconds, the transceiver will quit the VOX SET function automatically.
M5
See the MEM function on page 30.
12) 9/19 ~ DW ~ M4
9/19
(short press)
Press shortly the 9/19 key to select alternatively, channel 9 / channel 19 / and
current active channel. When an emergency channel is selected (9 or 19)
"EMG" is displayed on the LCD.
DW
(long press)
Push during one second the DW key in order to activate the DW (Dual Watch)
function. This function allows to survey between emergency channel (9 or
19) and the selected channel. The first long push activates the DW function
between channel 9 and the busy channel. "DW" is displayed.
A new long push activates the DW function between channel 19 and the busy
channel. The number of the selected channel and the emergency channel
(9 or 19) appears alternately on the display. The "EMG" icon is also displayed
at the same time as the emergency channel (9 or 19). The selected channel
can be modified during the dual watch.
A new long push on the DW key or pressing the the PTT key (17) disable the
DW function.
M4
See the MEM function on page 30.
13) ANL/NB/HICUT ~ SCAN ~ M3
ANL/NB/HICUT
(short press)
4 positions switch: Off / ANL and NB filters activated / HI-CUT activated / ANL
NB + HI-CUT activated. When active, the filter is displayed on the LCD.
ANL NB: Automatic Noise Limiter / Noise Blanker. These filters allow reducing
back ground noises and some reception interferences. In FM and USB/LSB
mode, only the NB filter is active.
HI-CUT: Cuts out the high frequency interferences and has to be used in
accordance with the reception conditions.
SCAN
(long press)
All Channel Scan Mode
Press the SCAN key in order to activate the SCAN function (scanning all the
channels) in upward direction. "SCAN" is displayed. The scanning stops as
soon as there is a busy channel.
Memory Channel Scan Mode
During the scan, press then MEM key (10) for activate the Memory Channel
Scan Mode and scan only the channels stored in memories. A new press in
the MEM key (10) return to the All Channel San Mode.
31