Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical data

Type
Rated voltage
Active power
Apparent output
Nominal force
Nominal locking force
Service life
Duty cycle
Housing
Protective system
Temp.range
Fire stability
Emission sound
pressure level
Nominal stroke length *
Additional functions *
* programmable with software SCS and BI-BT2 via Bluetooth
Normal operation =
fast-mode SHEV =
Stroke
DXD 150-BSY+ (-HS) DXD 300-BSY+ (-HS)
OPEN
1500 N
SB III
1000 N
SB II
1000 N
SB I
800 N
All forces + approx. 20%
cut-off reserve (temporary)
Closing edge protection
In the "CLOSE" direction the drive has an active
protection for the main closing edge. If there is an
overload in the closing range 3 and 2, the drive runs
"OPEN" for 10 seconds, then "CLOSE" again. If after
three attempts closing is not possible, the drive
remains in this position.
In addition, the drive is equipped with passive pinch
protection. The closing speed in closing range 2 and
1 is reduced to 5 mm/s.
Significantly greater forces can be
exerted at the secondary closing
edges. Danger of crushing hands and
fingers!
99.824.28 1.5/02/16
DXD 150-K-BSY+
DXD 150-K-BSY+HS
230 V AC, +10 % / -15 %, 50 Hz
35W
70W
50VA (cap.)
90VA (cap.)
1500 N
1500 N
1100 N
2200 N
>20 000 double strokes
30 % S2 (EN 60034-1), no continuous voltage
aluminium anodized / polycarbonate
IP 64 ("-W" = IP 54)
-5 ... +75°C
30 min / 300°C
LpA ≤ 70 dB(A)
see type plate
Closing-edge protection activated (3 repetitions of stroke)
3000 N
2000 N
1600 N
800 N
English
DXD 300-K-BSY+
70W
95VA (cap.)
3000 N
Running speeds and forces
main closing edge
DXD 150/300 -K-BSY+ (-HS)
DXD 300-K-BSY+ HS
140W
175VA (cap.)
3000 N
7/20