CAUTION:
Connect wires from molex plug to wire from
in-line blower (conduit) , connect same colors
(i.e: yellow with yellow, blue with blue etc.).
Molex plug
Yellow/Green
Close junction box cover.
From the inside of the hood connect the
molex plug from the electronic box to the
connector previously mounted on Junction
box.
Installation of the In-line blower:
2. Remove the front door -Unscrew all screws
that fix front door to the in-line blower unit
housing.
3. Disconnect the blowers connection plug.
4. Remove the screw that fixes the blower
assembly to its housing, pull the blower
fixing spring to release all assembly and
extract it.
5. Position the in-line blower unit housing in
place and with a pencil mark all fastener
locations and holes.
Note: all fastener location must span the
studs otherwise install each necessary
between studs firmly flush with already
existing stud front. Make sure all mounting
Front door
Junction
Box
Bottom fastener
(from range hood)
location
To In-Line
Red
Blower
White
Black
Grey
Blue
Motor Connection
Plug
inlet hole
screws will anchor to added studs.
6. Provide duct connection on the same side of
the keyholes used for fixing.
7. Fix the in-line blower unit housing with 4
screws.
8. In-line blower - Electrical connection:
Remove the knockout and the Junction box
cover and install the conduit connector
(cULUS) in junction box.
CAUTION:
Connect wires from range hood to wire from
in-line blower (molex plug) , connect same
colors (i.e: yellow with yellow, blue with blue
etc.).
From
Range
Hood
Close junction box cover.
9. Refit the blower assembly (in reverse order
as per step 4.
10. Refit the front door and provide the remaining
duct connection.
Turn power on in service panel.
Blower fixing
spring + screw
Bottom fastener
location
6
In-Line
Blower
Junction Box
Red
White
Black
Grey
Blue
Yellow/Green

Publicité