Section 3: Receiver Programming
Enroll & Program Devices
This section describes how to enroll and program:
• wireless devices using zones (WLS904PL-433, WLS906-433, WS4916, WLS912L-433, WLS914-433, WS4938,
WLS925L-433)
• wireless keys (WLS919-433, WS49X9)
For more information on these devices, read the instruction sheet included with each device.
3.1 Identified Wireless Keys
Reporting by the system of openings/closings by individual wireless keys and command output [*][7] activation by
wireless key buttons may be supported on certain control panels. To do this, the system will reserve access codes 17 –
32 for wireless keys 01-16 respectively. You must program one access code for each wireless key (using [*][5] access
code programming) for this feature to work correctly.
NOTE: Program these access codes on the system after you have connected the RF5132-433 to the Keybus (see
section 2.4).
Refer to your system Installation Manual for information on access code programming.
Opening/Closing By Wireless Key Reporting
NOTE: The Identified Wireless Key Closing option is only available with the PC5020, PC1616, PC1864, PC501X
v2.0 and higher, PC1555(MX), PC580/585 v2.0 and higher.
To enable the reporting of openings and closings by identified wireless keys:
• Make sure the control panel is v2.0 or higher
• Program a valid access code for each key
• Program a closing and opening reporting code for each key's access code
• Turn off the Quick Arm option in section [015] option [4] of the control panel programming
To ensure that an unidentified wireless key cannot disarm the system, turn off section [017], option [1] (in the control
panel programming). This option is available in control panels with software version 2.1 or higher.
3.2 A Note about Electronic Serial Numbers (ESN)
An electronic serial number (ESN) is printed on each wireless device. ESNs are used to enroll the wireless devices with
the RF5132-433 receiver.
In order to reduce the occurrence of wireless devices with the same serial number, 6-digit serial numbers are printed on
the back of each wireless device. The 6-digit serial numbers include hexadecimal digits. For instructions on
programming hexadecimal numbers, see your system Installation Manual, Section 4: How to Program.
NOTE: 6-digit serial numbers are only supported on the following control panels: PC5020, PC1616, PC1832,
PC1864, PC501X v2.0 & higher, PC1555(MX), PC580/585.
3.3 Enroll Wireless Devices Using Zones
Enroll wireless devices which use zones (universal transmitters, motion detectors, smoke detectors, and panic
pendants):
1. At a system keypad, enter [*][8][Installer's code] to go into the installer's programming section.
2. Enter programming section [804].
6