Can be washed in the dishwasher. It must be washed when Led S1 flashes or at least once
every 4 months, or more frequently if use is particularly intense. Guaranteed to operate after
washing for up to a maximum of 5 times before requiring replacement. The Alarm signal, if it
has been activated, only appears when the Suction motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date.
• Turn the Lights and the Suction Motor off.
• Press button T2 and hold it for 5 seconds until the LED flashes twice in confirmation:
CHANGING
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press T3 and hold for at least 3 seconds, until
LED flashes three times in confirmation.
Changing the Filter
• Open the doors.
• Remove the Metal Grease Filter.
• Remove the metal filter stops from the grease
filter and clean the saturated activated charcoal
odour filter.
• Replace the clean activated charcoal odour filter,
hooking it back up to the grease filter using the
metal filter stops.
• Replace the Metal grease filters.
• Close the doors.
Warning: This appliance is fitted with a white LED lamp classed
as 1M according to EN 60825-1: 1994 + A1:2002 + A2:2001
standards; maximum optical power emitted @439nm: 7µW. Do
not look directly at the light through optical devices (binoculars,
magnifying glasses...).
• For replacement contact technical support. ("To purchase con-
tact technical support")
EN
Activated Charcoal Filter (Recirculation Version)
Lighting unit
1 12