ABC2M-009_ES_FR_EN_PT_DE.book Page 48 Thursday, April 17, 2008 9:43 AM
PROGRAMMING AND STARTING UP
Programming of the partial/pedestrian opening radio code
4
PROGRAMMING FULL OPENING OF THE GATE
The programming of the pedestrian opening travel
of the gate can be done using the ST2 mini push
button, the wall key or the remote control.
Before making the programming, ensure there
is no person, animal or object in the radius of
action of the gate and the mechanism.
Automatic programming
Using this method, the travel of the leaves (opening
and closing stoppers) is programmed automatically,
as are the points at which the gates begin to slow
down when approaching the stoppers.
1 Place DIP1 and DIP5 in "ON" (automatic
programming); DIP2, DIP3, DIP4 and DIP6 in "OFF".
2 Place DIP7 in "ON" for instalations with two motors.
Place DIP7 in "OFF" for instalations with motor.
3 We recommend placing DIP8 in "ON" (slow down).
4 Press the full opening control (ST1, key or remote
control).
First leaf 2 is closed, followed by leaf 1, both at slow
speed through to the in-ground stop in closing.
48
Installation manual
1 Connect the power supply of the control panel
(SW1 in "ON").
2 Close the leaves by pressing ST1.
3 Place DIP1 and DIP 6 in "ON"; DIP2, DIP3, DIP4 and
DIP5 in "OFF".
DL3 lights up, flashing.
4 Select the required code in the transmitter.
5 Press the channel to be used for pedestrian opening.
If the programming has been made correctly,
DL3 lights up permanently.
6 Place DIP1 and DIP6 in "OFF" (DL3 will go off).
The programming of the full opening can be done in
two different ways:
• Automatically
(both
deceleration points are programmed automatically).
• Semi-automatically (the travel is programmed
automatically, but the deceleration points are
chosen manually).
5 DL3 lights up intermittently, and the opening and
closing operations for the two leaves (one leaf in
installations with one motor) are carried out at slow
speed.
6 DL3 lights up permanently, indicating that the
programming has finished.
The stoppers for the leaves both in opening and
closing will be memorised.
The positions in which the leaves begin to slow
down, both in opening and in closing, will also
be memorised.
7 Place DIP1 and DIP5 in "OFF".
DL3 shall remain off.
the
travel
and
the