Carrier 39SQC/R/P Instructions De Fonctionnement page 36

Table des Matières

Publicité

Adresse/numéro
Adresse LB
de registre
du registre
67 [h43]
1080 [h438]
68 [h44]
1096 [h448]
69 [h45]
1112 [h458]
70 [h46]
1128 [h468]
71 [h47]
1144 [h478]
72 [h48]
1160 [h488]
73 [h49]
1176 [h498]
74 [h4A]
1192 [h4B8]
75 [h4B]
1208 [h4B8]
76 [h4C]
1224 [h4A8]
77 [h4D]
1240 [h4B8]
78 [h4E]
1256 [h4C8]
79 [h4F]
*
80 [h50]
*
81 [h51]
*
82 [h52]
*
83 [h53]
*
84 [h54]
*
85 [h55]
*
86 [h56]
*
87 [h57]
*
88 [h58]
*
89 [h59]
*
90 [h5A]
*
91 [h5B]
*
92 [h5C]
*
93 [h5D]
*
94 [h5E]
*
95 [h5F]
*
96 [h60]
*
97 [h61]
*
98 [h62]
*
99 [h63]
*
100 [h64]
*
101 [h65]
*
102 [h66]
*
103 [h67]
*
104 [h68]
*
105 [h69]
*
106 [h6A]
*
107 [h6B]
*
108 [h6C]
*
109 [h6D]
*
110 [h6E]
*
111 [h6F]
*
112 [h70]
*
113 [h71]
*
114 [h72]
*
115 [h73]
*
116 [h74]
*
117 [h75]
*
118 [h76]
*
119 [h77]
*
120 [h78]
*
121 [h79]
*
122 [h7A]
*
123 [h7B]
1720 [h6B8]
124 [h7C]
1736 [h6C8]
125 [h7D]
1752 [h6D8]
126 [h7E]
1768 [h6E8]
127 [h7F]
1784 [h6F8]
128 [h80]
1800 [h708]
129 [h81]
1816 [h718]
130 [h82]
1832 [h728]
131 [h83]
1848 [h738]
132 [h84]
1864 [h748]
133 [h85]
*
134 [h86]
*
135 [h87]
*
*
Ne s'applique pas à ce type de registre.
36
Accès
Point/table
Description
JBus
R
Marquage de mise à jour du point de consigne 1 La valeur est réglée à 1 lorsqu'une opération
R
Marquage de mise à jour du point de consigne 2
R
Marquage de mise à jour du point de consigne 3
R
Marquage de mise à jour du point de consigne 4
R
Marquage de mise à jour du point de consigne 5
R
Marquage de mise à jour du point de consigne 6
R
Marquage de mise à jour du point de consigne 7
R
Marquage de mise à jour du point de consigne 8
R
Marquage de mise à jour du point de consigne 9
R
Marquage de mise à jour du point de consigne
10
R
Marquage de mise à jour du point de consigne
11
R
Marquage de mise à jour du point de consigne
12
R
Écriture point de consigne 1 - état
R
Écriture point de consigne 2 - état
R
Écriture point de consigne 3 - état
R
Écriture point de consigne 4 - état
R
Écriture point de consigne 5 - état
R
Écriture point de consigne 6 - état
R
Écriture point de consigne 7 - état
R
Écriture point de consigne 8 - état
R
Écriture point de consigne 9 - état
R
Écriture point de consigne 10 - état
R
Écriture point de consigne 11 - état
R
Écriture point de consigne 12 - état
R/W
Marquage forçage 1
R/W
Marquage forçage 2
R/W
Marquage forçage 3
R/W
Marquage forçage 4
R/W
Marquage forçage 5
R/W
Marquage forçage 6
R/W
Marquage forçage 7
R/W
Marquage forçage 8
R/W
Marquage forçage 9
R/W
Marquage forçage 10
R
Forçage/auto #1 - état
R
Forçage/auto #2 - état
R
Forçage/auto #3 - état
R
Forçage/auto #4 - état
R
Forçage/auto #5 - état
R
Forçage/auto #6 - état
R
Forçage/auto #7 - état
R
Forçage/auto #8 - état
R
Forçage/auto #9 - état
R
Forçage/auto #10 - état
R/W
wd_r_111
Point de consigne #1
R/W
wd_r_112
Point de consigne #2
R/W
wd_r_113
Point de consigne #3
R/W
wd_r_114
Point de consigne #4
R/W
wd_r_115
Point de consigne #5
R/W
wd_r_116
Point de consigne #6
R/W
wd_r_117
Point de consigne #7
R/W
wd_r_118
Point de consigne #8
R/W
wd_r_119
Point de consigne #9
R/W
wd_r_120
Point de consigne #10
R/W
wd_r_121
Point de consigne #11
R/W
wd_r_122
Point de consigne #12
R/W
fv_r_123
Valeur forcée #1
R/W
fv_r_124
Valeur forcée #2
R/W
fv_r_125
Valeur forcée #3
R/W
fv_r_126
Valeur forcée #4
R/W
fv_r_127
Valeur forcée #5
R/W
fv_r_128
Valeur forcée #6
R/W
fv_r_129
Valeur forcée #7
R/W
fv_r_130
Valeur forcée #8
R/W
fv_r_131
Valeur forcée #9
R/W
fv_r_132
Valeur forcée #10
R/W
jbus_add/JBUSCONF Vitesse de transmission en bauds du JBus
R/W
jbus_bau/JBUSCONF Adresse du JBus
R/W
jbus_par/JBUSCONF
Bit de parité et d'arrêt du JBus
Remarques
d'écriture du point de consigne est requise par
JBus. Lorsque l'opération d'écriture est
terminée, cette marquage revient à 0.
0 = fonctionnement obtenu
1 = accès refusé
2 = échec de communication avec le CCN
3 = fonctionnement en cours
-1 = format interdit
Cette valeur est réglée sur 1 lorsqu'une
opération de forçage est requise par JBus.
Lorsque l'opération de forçage est terminée,
cette marquage revient à 0.
Cette valeur doit être réglée sur 2 lorsque on
veut auto.
0 = fonctionnement obtenu
1 = accès refusé
2 = échec de communication avec le CCN
3 = fonctionnement en cours
-1 = format interdit
Les points de consigne doivent être écrits dans
la commande CCN par le JBus hors réseau.
Les registres 79 à 90 donnent l'état de
l'opération d'écriture.
Les valeurs à forcer dans la commande CCN
qui doivent être écrites par le JBus hors réseau.
Les registres 101 à 110 donnent l'état de
l'opération de forçage.
Les valeurs à forcer dans la commande CCN
qui doivent être écrites par le JBus hors réseau.
Les registres 101 à 110 donnent l'état de
l'opération de forçage.
Accessible par le JBus et le CCN.