CONNECTIONS TO TERMINAL BOARD
FS1 - FS2
board supply input 13,5 Vac – Powered by the toroidal transformer housed in the T-
ONE5B motor and protected by a fuse on the 230 Vac power supply.
1 - 3
(Fixed safety edge) SENSITIVE EDGE input (resistive sensitive edge or fixed safety
edge); Works only when the gate is opening; temporarily stops the gate and partially
closes it by about 20 cm in order to allow the obstacle to be removed.
1= SENSITIVE EDGE, 3= COMMON.
If a resistive sensitive edge is connected, set dip-switch no. 9 to ON;
If a fixed safety edge with NC contact is connected, set dip-switch no. 9 to OFF.
2 - 3
(Photocell) input for PHOTOCELLS OR SAFETY DEVICES active during closure (Nor-
mally Closed contact); They stop the gate during closing and totally reopen it; they tem-
porarily stop the gate during opening in order to allow the obstacle to be removed (if dip
switch n° 3 set to ON). If there is more than one safety device, connect all the NC contacts
IN SERIES. 2= PHOTOCELL.
The photocell transmitter must always be supplied by terminals no. 10 - 11, since the
safety system test (phototest) is carried out on it. To override the testing of the safety
system, or when the photocells are not used, set dip-switch no. 6 to OFF. If the pho-
totest is not successful, the control unit will not operate.
4 - 5
(Stop) STOP pushbutton input (Normally Closed contact); It stops the gate in any position,
temporarily inhibiting its automatic closing, if programmed.
4= COMMON, 5= STOP.
4 - 6
(Open/Close) OPEN/CLOSE pushbutton input (Normally Open contact); It commands the
opening and closing of the gate and its operation is controlled by dip-switches 2 and 4. 5=
OPEN/CLOSE.
4 - 7
(Pedestrian) PEDESTRIAN pushbutton input (Normally Open contact); It commands the
partial opening and closing of the gate for ~1 m of travel and its operation is controlled by
dip-switches 2 and 4. 7= PEDESTRIAN.
8 - 9
(Photocell RX ) 18 Vdc, max. 15 W, output to POWER THE RXs AND ANY OTHER
TXs OF PHOTOCELLS THAT ARE PRESENT, EXTERNAL RECEIVERS, etc.; connect a
max. of 3 pair of photocells. 8= NEGATIVE, 9= POSITIVE.
10 - 11
(Photocell TX) 18 Vdc, output for PHOTOCELL TX (only the one that performs the Pho-
totest) max. no. 1 photocell transmitter. 10= NEGATIVE, 11= POSITIVE.
12 - 13
(Flashing light) FLASHING LIGHT output 18 Vdc, max. 20 W. The signal is already mod-
ulated for direct use. Flashing frequency during closing is double.
12= NEGATIVE, 13= POSITIVE.
14 - 15
(Gate open warning light) GATE OPEN LED output 18 Vdc, max. 3 W; during opening
of the gate the warning light flashes slowly, when the gate is open it remains steadily il-
luminated and during closure it flashes twice as fast.
14= NEGATIVE, 15= POSITIVE.
16 - 17
(2nd radio channel) 2nd RADIO CHANNEL output (its operation depends on dip-switch-
es nos. 7 - 8) to be used for opening/closing another gate, for controlling garden lights or
for the "ZONE LIGHTING" function.
18 - 19
(Antenna) 433,92 MHz built-in RX ANTENNA input.
18= EARTH, 19= SIGNAL.
K125M
15