Technical characteristics

6.
Environmental:
Operating temperature:
0°C - 40°C
Shipping and storage
temperature:
-10°C to +50°C
Electrical Protection
IP30
Installation Category
Class II
Pollution Degree
2
Measured temperature
0.1°C
precision
Setting temperature range
Comfort, Reduced
5°C to 35°C by 0,5°C step
Holiday (Antifreeze)
10°C (adjustable)
Timer
5°C to 35°C
Proportional Band (PWM
Regulation characteristics
2°C for 10min cycle) or
Hysteresis of 0.5°C
Power Supply
2 AAA LR03 1.5V Alkaline
Operating life
~2 years
Sensing elements:
Internal & External (option)
NTC 10k at 25°C
My BT DRF-01 seems work correctly but the heating doesn't
work correctly
On the receiver:
- check the good reception of RF signal
- Check the connections.
Output
- Check the power supply of the heating
element.
- Contact your installer.
- Check the following points :
- The receiver must be put at a minimum
RF
distance of 50cm of all others electrical
communicati
or wireless materials (GSM, Wi-Fi..)
on
- The receiver shouldn't be fixed on a
metallic part or too close of hydraulic
pipes... (Copper...)
My BT DRF-01 seems work correctly but the temperature
in the room was never in accordance with the setting
temperature.
- Try to calibrate your thermostat (see user
menu parameter 04)
Program
- Contact your installer, to check & adjust
the regulation parameters with your
heating system.
28
Radio Frequency
868 MHz, <10mW.
Showed in the parameter
Software version
menu. Vers xxx
EN 60730-1 : 2003
EN 61000-6-1 : 2002
EN 61000-6-3 : 2004
Norms and homologation:
EN 61000-4-2 : 2001
Your thermostat has been
EN300220-1/2
designed in conformity with
EN301489-1/3
the following standards or
other normative documents:
R&TTE 1999/5/EC
Low voltage 2006/95/CE
EMC 2004/108/CE
26
29
Troubleshooting & Solution
7.
My BT DRF-01 doesn't start
- Check if the protection sticker on the
batteries is removed.
Batteries Problem
- Check the batteries orientation.
- Check the capacity of the batteries
My BT DRF-01 Led, blinks in Red
The logo blinks (ambient sensor)
- Contact your installer or seller.
Problem on
sensors
The logo blinks (Floor sensor)
- Check the connection of the sensor.
- Disconnect the sensor, and check it
with an ohmmeter
(the value must be around 10kohms)
Batteries level is
The logo blinks (Batteries)
too less
- Replace the batteries.
27
IMPORTANT!
- Avant de commencer les travaux, le monteur doit lire,
comprendre et observer les présentes instructions de montage et
de service.
- Seul un spécialiste en la matière est autorisé à effectuer le
montage, le réglage et la maintenance du thermostat. Un monteur
en formation ne peut réaliser de travaux sur l'appareil que sous la
surveillance d'un expert. La responsabilité du fabricant
conformément aux dispositions légales s'applique uniquement
dans le cas du respect des conditions précitées.
- Veuillez observer l'ensemble des instructions de montage et de
service lors de l'utilisation du thermostat. Toute utilisation autre
n'est pas conforme. Le fabricant ne répond pas des dommages
occasionnés par une utilisation abusive du thermostat. Pour des
raisons de sécurité, aucune transformation ou modification n'est
admise. Seuls les ateliers de réparation désignés par le fabricant
sont habilités à réparer le matériel.
- Le contenu de la livraison de l'appareil varie selon le modèle et
l'équipement. Sous réserve de modifications techniques !
Il est recommandé que l'installateur et l'utilisateur prennent
connaissance de l'intégralité de la notice, avant de procéder à
l'installation du matériel.
30

Publicité

Table des Matières
loading

Table des Matières