Technical Characteristics; Troubleshooting & Solution - Watts Industries BT DP-01 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
hour programmed following your weekly program.
This automatic control system works in the following
way:
When you start your thermostat for the first time, it will
measure the time taken by your installation to reach
the set temperature. The thermostat will re-measure
this time at each program change to compensate
external temperature change & influence. You can now
program your thermostat without the need to adjust the
temperature in advance because your thermostat does
it automatically for you.
Clr ALL: Reset to Factory setting
08
Press and maintain (Ok) key during 10s to reset Set
points temperatures and user parameters in this menu
to factory default settings. User programs will also be
resetted.
* Pay attention:
Ensure you that you have all necessary elements to re-
setup your installation before to use this function.
Software version
09
VErS ___
End: Exit the parameter's menu
10
Press (OK) key to exit installation parameter menu and
7
Troubleshooting & Solution
My BT DP-01 doesn't start
- Check if the protection sticker on the
batteries is removed.
Batteries
- Check the batteries orientation.
Problem
- Check the capacity of the batteries
My BT DP-01 Led, blinks in Red
The logo blinks (ambient sensor)
- Contact your installer or seller.
Problem on
sensors
The logo blinks (Floor sensor)
- Check the connection of the sensor.
- Disconnect the sensor, and check it
with an ohmmeter
(the value must be around 10kohms)
Batteries level is
The logo blinks (Batteries)
too less
- Replace the batteries.
return to normal operation.
6

Technical characteristics

Measured temperature
precision
Environmental:
Operating temperature:
Shipping and storage
temperature:
Setting temperature range
Comfort, Reduced
Holiday (Antifreeze)
Timer
Regulation characteristics
Electrical Protection
Power Supply
Operating life
Receiver Output
Maximum load
37
My BT DP-01 seems work correctly but the heating doesn't
Output
My BT DP-01 seems work correctly but the temperature in
the room was never in accordance with the program.
Program
40
0.1°C
0°C - 40°C
-10°C to +50°C
5°C to 35°C by 0,5°C step
10°C (adjustable)
5°C to 35°C
Proportional Band (PWM
2°C for 10min cycle) or
Hysteresis of 0.5°C
Class II - IP30
2 AAA LR03 1.5V Alkaline
~2 years
Relay 5Amps 250Vac
3A in 230Vac (Free contact)
38
work correctly
- Check the connections.
- Check the power supply of the
heating element.
- Contact your installer.
- Check the Clock.
-The difference between Comfort &
Reduced temperature is too high?
- The step in the program is too
short?
- Contact your installer, to check &
adjust the regulation parameters
with your heating system.
41
Optional External sensor
10k ohms at 25°C
Displayed in the user
Software version
menu.
EN 60730-1 : 2003
Norms and homologation:
EN 61000-6-1 : 2002
EN 61000-6-3 : 2004
Your thermostat has been
EN 61000-4-2 : 2001
designed in conformity with the
following standards or other
Low voltage 2006/95/CE
normative documents:
EMC 2004/108/CE
39
42

Publicité

Table des Matières
loading

Table des Matières