Installing a domestic appliance can be a complicated operation which, if not
carried out correctly, can seriously affect consumer safety.
It is for this reason that the task should be undertaken by a professionally
qualified person who will carry it out in accordance with the technical regulations
in force.
In the event that this advice is ignored and the installation is carried out by an
unqualified person, ROSIERES declines all responsibility for any technical failure
of the product whether or not it results in damage to goods or injury to
individuals.
INSTALLATION: "ELECTRICAL CONNECTION"
The mains electricity supply connected to the appliance should comply with the norms in
force in the country of installation.
Rosières declines all responsibility for any damage that may be caused by unsuitable or
unreasonable use.
Warning :
• Always check before any electrical operation, the supply voltage shown on the
electricity meter, the adjustment of the circuit-breaker, the continuity of the
connection to earth of the installation and that the fuse is suitable.
• The electrical connection to the installation should be made via a socket with a plug
with earth, or via an omnipole cut-out switch with an opening gap of at least 3 mm.
• The yellow/green wire of the power supply cable must be connected to the earth
of both power supply and appliance terminals.
• Rosières cannot be held responsible for any accidents resulting from the use of an
appliance which is not connected to earth, or with a faulty earth connection continuity.
• Any queries regarding the power supply cord should be referred to After Sales
Service or a qualified technician.
The hob "TC 04" is equipped with a supply cord type H05RR-F - area 3G2,5 mm²
This power cord enables you to connect to exclusively single phase 220-240 V~ or two
phase 220-240 V2~.
However it can be modified for connection to :
• Three phase
• Three phase

INSTALLATION

220-240 V3~
380-415 V3N~